Page 29
ENGLISH
Installation and Operation Manual
|
Jandy
®
LXi
™
Model Pool and Spa Heater by Zodiac
®
Figure 29. Wiring an LXi to a Zodiac RS Remote
RESET
SERVICE
TIME OUT
FIL
TE
R PUM
P
AU
X 1
AU
X 2
AUX
3
AUX
4
AUX
5
AU
X 6
AUX
7
RS6 & RS8 ONLY
RS8 ONLY
HEATER
SOLAR
POOL MODE
SPA MODE
SPA DRAIN
SPA FILL
AUTO
6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
4 3 2 1 4 3 2 1
To Sensors, etc.
(green terminal bar)
To Remote
(brown terminal bar)
To Controller
(red terminal bar)
GR Y BK R
4 3 2 1
Power Center
Indoor Controller
LXi Control
RS Control
System
Power
Center
Bezel
22 Gauge
4 Conductor
Wire
Do not connect more than two (2) wires to any
of the terminals in the RS Control System when con-
necting peripheral devices. If connecting the LXi heater
to the RS Control System creates this situation, then a
Multiplexing PCB kit must be used. Call your distribu-
tor or Zodiac Pool Systems, Inc., to order the kit.
To connect the LXi to your RS control system,
refer to Figure 29 and follow the steps listed below.
1. Turn off the power to both the heater and the RS
control.
2
Open the RS Power Center enclosure and remove
the front dead panel.
NOTE
Only an RS System with firmware revision "N",
or higher, will support the LXi heater interface.
Refer to Table 7 and Figures 27 and 28 to
determine the REV of your system's firmware.
If it is "N" or higher, continue with these
procedures. If it is MMM or lower, follow the
procedures in
Section 6.5.2.
NOTE
Only a PDA System with firmware revision 4.1,
or higher, will support the LXi heater interface.
3. Use 22 gauge 4-conductor wire (Zodiac
part # 4278) to run between the heater and the
RS control, and match the wire color order.
4. The wires coming from the LXi heater can be
“doubled up” on the red terminal bar with the
four (4) wires coming from the indoor controller.
Summary of Contents for Jandy LXi