![background image](http://html1.mh-extra.com/html/zodiac/jandy-lxi/jandy-lxi_installation-and-operation-manual_936446049.webp)
Page 49
ENGLISH
Installation and Operation Manual
|
Jandy
®
LXi
™
Model Pool and Spa Heater by Zodiac
®
Figure 39. Test Point Identification Diagram
L1
F1
ACN1
ACH1
L2
F2
G
R
BK
240 VAC
HEATER
POWER
SUPPLY
BLOWER
MOTOR
W
BK
BL
R
O
IGNITION CONTROL
F1
F2
24
VAC
FV+ FV-
IGN
120 L1 L2
IGN
FS
W
GND
VAL
BK
W
BK
BL
R
GY
BK
24 VAC
R
Y
HOT SURFACE
IGNITER
W
GY
W
FLAME SENSE
TRANSFORMER
BK
WATER
TEMP
GAS
VALVE
USER
INTERFACE1
BK O BL R
HIPRESS/
HILIMIT
LOPRESS/
FUSELINK
WATER
PRESS
REMOTE
SPA POOL COM
REV
VALVE
24VAC
PUMP
COMP/
IGN
FAN/
LOUVER
JVA
INTAKE
JVA
RETURN
UNIVERSAL
CONTROLLER
POWER INTERFACE
UNIVERSAL
CONTROLLER
USER INTERFACE
POWER
INTERFACE
BK O BL R
AIR FLOW
SWITCH
GAS VALVE
WATER
TEMP
SENSOR
BL
W
BK
TO PUMP STARTER
CONTACTS (IF USED)
TO COMBUSTION
AIR LOUVER STARTER
(IF USED)
W
FUSE
R
Y
O
BK/Y
O
Y/BK
O
BR
Y
BR
Y
R
BL
BK
BK
BK
W
BK
BL
BR
Y
BK
BK
BK
BL
O
V
GY
BK
BK
PSW
Y/BK
C
NO
NC
Y/BK
COIL/AIR
TEMP
O
Factory Wired 24V
Factory Wired 120V/240V
BK - BLACK
BK/Y - BLACK WITH YELLOW TRACE
BL - BLUE
BR - BROWN
G - GREEN
GY - GRAY
O - ORANGE
R - RED
V - VIOLET
W - WHITE
Y - YELLOW
Y/BK - YELLOW WITH BLACK TRACE
120 VAC
HEATER
POWER
SUPPLY
Alternate 120V Wiring*
G
R
BK
NEUTRAL
HOT
Voltage Selector Card Must Be Rotated.
LIMIT
SWITCH
55˚C
(130˚F)
LIMIT
SWITCH
65˚C
(150˚F)
ROLL-OUT
(FUSIBLE
LINK)
152˚C
(306˚F)
WATER
PRESS
SWITCH
VENT
TEMPERATURE
LIMIT
240˚C
(464˚F)
10
3
4
5
6
7
8
9
C
B
I
H
J
1
K
12 11
13 14
D
E
F
2
Summary of Contents for Jandy LXi