Zodiac Pool Systems, Inc., requires that the ap-
pliance be connected to a “bonding loop” that includes
all electrical equipment in the system and on the
equipment pad. Bonding lugs must be connected with
a solid copper wire not smaller than 8 AWG (6 AWG
in Canada). Failure to do so will void the Zodiac Pool
Systems, Inc. warranty.
Additionally, in the United States the National
Electrical Code
®
(NEC) and in Canada the Canadian
Electrical Code
®
(CEC), require that all metallic
components of a pool structure, including reinforcing
steel, metal fittings and above ground components be
bonded together (forming an “equipotential bonding
grid”) with a solid copper conductor not smaller than
an 8 AWG (6 AWG in Canada).
The NEC and CEC also require that the equip-
ment and/or appliances associated with the pool water
circulating system, including, but not limited to, pump
motors and heaters, be bonded together as part of the
equipotential bonding grid. Zodiac Pool Systems, Inc.
provides a special labeled bonding lug on the right side
of the heater to accommodate this requirement.
6.4
Optional Pump Connection
(Maintain Temp Feature)
This optional feature allows the heater to turn
on the pool pump, bypassing the time clock setting,
to maintain the desired temperature. In order for the
MAINTAIN TEMP feature to be functional, a relay
must be installed and a dedicated line from the pool
pump time clock to the Maintain Temp (Pump) Relay
is needed. See Figure 24. The relay and pertinent
instructions can be obtained by ordering Zodiac part
number R0467200.
6.5
Optional Remote Controls
WARNING
RISK OF ELECTRIC SHOCK WHICH CAN RE-
SULT IN SERIOUS INJURY OR DEATH. Before
attempting installation or service, ensure that all
power to the device is disconnected/turned off at
the circuit breaker.
AVERTISSEMENT
RISQUE DE CHOC ÉLECTRIQUE POUVANT
CAUSER DES BLESSURES GRAVES OU LA
MORT. Avant de tenter l’installation ou d’utiliser le
service, assurez-vous que l’alimentation allant vers
le dispositif soit débranchée/éteinte au niveau du
disjoncteur du circuit. Branchez seulement à un
circuit protégé par un disjoncteur de mise à la terre.
Electrical wiring must be in accordance with the
latest edition of the National Electric Code (NEC),
ANSI/National Fire Protection Association
®
(NFPA)
70, unless local code requirements indicate otherwise.
INTERMATIC MODEL T104 MECHANICAL TIMER
(NOT PROVIDED WITH HEATER)
INTERMATIC MODEL T104 (NOT PROVIDED WITH HEATER) WIRE CONNECTIONS SHOWN AS AN EXAMPLE,
OTHER MODELS MAY HAVE DIFFERENT CONNECTIONS. CONSULT TIMER MANUFACTURER FOR PROPER CONNECTIONS.
FIELD INSTALLED COMPONENTS
OPTIONAL HEATER COMPONENTS
MAINTAIN TEMP (PUMP) RELAY
(SEE HEATER WIRING DIAGRAM)
240 VAC
PUMP
CLOCK
MOTOR
NOTE:
EQUIPMENT
GROUND
L2
L1
1
3
2
4
Figure 24. Example of Maintain Temp Wiring to the Time Clock