background image

H0638700_REVI - 2021/06

More documents on:

www.zodiac.com

Z400iQ

EN

Instructions for installation and use

 - 

English

 

Heat 

pump

Translation of the original instructions in French

Summary of Contents for iAquaLink Z400iQ

Page 1: ...H0638700_REVI 2021 06 More documents on www zodiac com Z400iQ EN Instructions for installation and use English Heat pump Translation of the original instructions in French...

Page 2: ......

Page 3: ...r instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance This appliance can be used by ch...

Page 4: ...orm maintenance or servicing operations on the appliance with wet hands or if the appliance is wet Before connecting the appliance to the source of supply ensure that the terminal block or supply sock...

Page 5: ...h the consequent risk of severe burns TROUBLESHOOTING All soldering work must be carried out by a someone qualified to do so Replacement pipes must always be made of copper in compliance with standard...

Page 6: ...working order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer it in doubt The reco...

Page 7: ...14 Maintenance 15 3 1 I Winterizing 15 3 2 I Maintenance 15 Troubleshooting 18 4 1 I Appliance behaviour 18 4 2 I Error code display 19 4 3 I Lighting of LEDs on the printed circuit board 20 4 4 I Wir...

Page 8: ...grated under its base height adjustable on a stable solid and level surface This surface must be able to bear the weight voir 5 2 I Technical specifications of the appliance in particular in the case...

Page 9: ...ns Install 50 cm of flexible PVC pipe at the heat pump water inlet and outlet to absorb vibrations Increase the filtration time by 50 and activate silence mode The heat pump will run for longer with l...

Page 10: ...valve by pass valve water outlet valve water inlet adjustment valve optional water outlet adjustment valve optional water treatment minimum distance To evacuate the condensates fit a 18 pipe on the g...

Page 11: ...curve rating to be defined according to the table 5 2 I Technical specifications with a suitable dedicated differential protection device circuit breaker or switch Additional protection may be requir...

Page 12: ...isk of interference using a collar inside the appliance just after the glands 1 5 1 Heating priority option This function helps to keep the water temperature constant by checking the water temperature...

Page 13: ...will have enough operating range to heat up Cover the pool with a sheet bubble canopy canvas etc to prevent heat loss The heat pump will be even more efficient if it operates during the warmest hours...

Page 14: ...see 4 2 I Error code display Off Stopped Device off or not connected to the power supply 2 3 I Operation Check that there are no tools or other foreign objects in the machine The panel that provides...

Page 15: ...the temperature setpoint is displayed and flashes Press to increase the temperature by 0 5 C Press to reduce the temperature by 0 5 C Press to confirm the desired setpoint temperature The settings scr...

Page 16: ...the setpoint temperature to at least 2 degrees below the measured water temperature 2 5 I Connection to the iAquaLink app The Z400iQ heat pump may be controlled by remote from a smartphone or tablet v...

Page 17: ...operations are carried out at the user s expense by a qualified technician 3 2 1 Safety instructions concerning appliances containing R32 refrigerant Z400iQ MD4 MD5 TD7 TD8 TD9 models Area check Prio...

Page 18: ...all include damage to cables excessive number of connections terminals not made to original specification damage to seals incorrect fitting of glands etc Ensure that the apparatus is mounted securely...

Page 19: ...is available if required for handling refrigerant cylinders all personal protective equipment is available and being used correctly the recovery process is supervised at all times by a competent perso...

Page 20: ...low below 12 C The appliance is smoking The machine has come to the end of the defrost cycle water has changed to gaseous state and passes through the grid If your heat pump is not in its defrost cycl...

Page 21: ...ng red LED press Cooling circuit high pressure fault Exchanger clogged with dirt Clean the water exchanger Steady red LED automatic Flashing red LED press Insufficient water flow Increase flow using t...

Page 22: ...s Condenser protection ST1 sensor temperature too low Wait until the water temperature rises above 35 C or switch to Hot mode if the appliance is in Cooling mode Automatic 4 3 I Lighting of LEDs on th...

Page 23: ...teristics 5 1 I Description In the appliance s box A Z400iQ B Winterizing cap x2 C 50 connector to be glued x2 D Winterizing cover Heating priority E PAC NET cleaning product supplied available as an...

Page 24: ...A Boost 64 65 66 68 64 65 64 66 Silence 61 63 63 66 61 62 62 63 Frequency band GHz 2 412 2 484 Emitted power dBm 20 Type of refrigerant R32 R410A R32 R410A R32 R410A R32 Refrigerant amount kg 0 87 1 0...

Page 25: ...1030 1145 B 450 480 C 479 509 D 880 1027 Overall dimensions in mm Front Side Rear Base Front panel Grid User interface Appliance status LEDs Side panel Technical access door Technical access door Poo...

Page 26: ...Sch mas lectriques Wiring diagrams Schaltplan Elektrischschema Esquema el ctrico Esquema el ctrico Schema elettrico 1 Z400iQ MD4 MD5...

Page 27: ...2 Z400iQ MD7...

Page 28: ...3 Z400iQ MD8...

Page 29: ...4 Z400iQ MD9...

Page 30: ...5 Z400iQ TD7 TD8 TD9...

Page 31: ...ature sensor Fl ssigkeitstemperatur f hler Temperatuursensor vloeistof ST5 Sonde temp rature refoulement Compressor discharge temperature Temperaturf hler an Druckseite Temperatuursensor perszijde LP...

Page 32: ...ra de l quido Sonda temperatura liquida ST5 Sonda de temperatura de descarga Sonda temperatura retorno Sonda temperatura di mandata LP Presostato de baja presi n Pressostato baixa press o Pressostato...

Page 33: ...eil Appliance model Num ro de s rie Serial number EUROPE ZPCE ZA La Balme 31450 Belberaud S A S U au capital de 1 267 140 SIRET 395 068 679 00046 RCS TOULOUSE AUSTRALIA Zodiac Group Australia Pty Ltd...

Reviews: