44
5.3.4 Confi guring the ORP setpoint
The ORP setpoint confi gurati on determines the ti me at which chlorine is produced by the appliance. The level of free
chlorine must be controlled at regular intervals aft er initi al installati on.
The default value of the ORP setpoint is 700 mV.
The value of the setpoint depends on the pool's environment, its affl uence, and the amount of stabiliser present in the
pool water, etc.
• Press
and browse the menu using the
butt ons. Press
to
confi rm.
•
Select the desired setpoint value (from 600 mV to 900 mV)
using the
butt ons.
• Press
to confi rm.
5.3.5 Acti vati ng the pH pump
To prevent exposure to acid during installati on, the dispenser pump is deacti vated for the fi rst 8 hours of operati on;
during these fi rst 8 hours, the pH value is measured and displayed as "- - - -".
• Hydrochloric acid is a hazardous chemical that may cause burns, lesions and irritati ons.
Handle with care and use protecti ve equipment (gloves, safety glasses, overalls). Refer to the
product's MSDS for more informati on.
• Always pour the acid into the water.
• Once cleaning is complete, dispose of the soluti on according to the standard in force in the
country of use.
•
The pH pump can be manually acti vated during this 8-hour period; press
and browse the menu
using the
butt ons.
Press
to
confi rm.
• Press
to exit.