XPLC300 Motion Controller Hardware Manual V1.5
4.2.2.
Local Analog Offset Configuration
Functional Description
It is used to offset local AIO address of XPLC300 controllers.
Grammar
LOCALAIO_OFFSET=value
Parameter List
value
AIO starting address
Default: 0
Example
LOCALAIO_ADDRESS=8
‘
local AIO address is offset to 1
Note: there is no analogs for XPLC300 series controllers, no offset configuration effect.
4.2.3.
IO Offset Configuration for ZMIO Expansion (that
comes with XPLC300 controller)
Functional Description
It is used to offset local IO address of ZMIO300 expansion
that comes with XPLC300 controllers.
Grammar
ZMIO_OFFSET=value
Parameter List
value
IO starting address
Default: multiples of 32 and 8
Example
ZMIO_ADDRESS=48
‘
local IO address brought by ZMIO expansion is offset to 48
Note: IO starting address only can be set as the multiple of 8.
Controller status (before modification):
Controller status (after modification):
4.2.4.
Analog Offset Configuration for ZMIO Expansion
(that comes with XPLC300 controller)
Functional Description
It is used to offset local AIO address of ZMIO300 expansion
that comes with XPLC300 controllers.
Summary of Contents for XPLC300
Page 1: ......