Factory Defaults (Eight passwords for opening the door are set to 0 
after reset)

 

Parameters  Type 

Defaults 

Unlocking Duration 

6s 

Verification Mode 

Fingerprint/Password/RF Card 

Door Sensor Type

 

None 

Alarm Switch 

enable 

Administrator       

Authentication Alarm 

enable 

Tamper Alarm 

enable 

Door Sensor Delay 

10s 

Technical Specifications 

Fingerprint  Collector 

SilkID

 

Fingerprint Reader

 

Key  Type 

Touch key 

User

 

Capacity

 

500 

Fingerprint Capacity 

500 

Card Capacity 

500 

Access Control Function 

Unlocking, Alarm, Lock driver time length

 

Alarm Function 

Tamper Alarm, Failed Authentication Alarm, Door 
Sensor Alarm 

Doorbell 

External wired doorbell

 

 

 

Summary of Contents for X8-BT

Page 1: ...User Manual X8 BT Version 1 0 Date August 2019 ...

Page 2: ...om the bottom of the device 2 Remove the back cover of the device 3 Fix the back cover on the wall Drill the wiring hole and fixing holes according to the back cover 1 Remove the screws from the bottom of the device 2 Remove the back cover of the device 3 Fix the back cover to 86 box on the wall 4 Install the device on the back cover The back cover is fixed on the 86 box 5 Fix the device on the ba...

Page 3: ... NC1 AL AL BELL BELL NO1 DC12V DC12V 12V GND BUT GND SEN COM1 NC1 AL AL BELL BELL NO1 DC12V The device shares power with the lock when ULOCK 12V and I ILOCK 1A and the lock is near to the device The device does not share power with the lock A When ULOCK 12V and I ILOCK 1A B When ULOCK 12V C When the lock is far apart from the device Lock Door Sensor Exit Button Bell Alarm NC Lock NC Lock Access Co...

Page 4: ...D COM1 NO1 12V GND NC PUSH NO GND 通电常闭锁 V V 12V GND COM1 NO1 门禁机1 门禁机2 专业门禁电源 Only devices with an alarm consuming 12V DC can be connected Input 12V DC 500mA 50mA in idle status Positive is connected with 12V negative is connected with GND do not reverse the polarities 4 Connection with Other Devices Access Control Device Professional Access Control Power Access Control Device 2 Access Control Dev...

Page 5: ...he indicator turns green and makes a long beep Press finger three times The indicator turns green and makes a long beep Enter 1234 The indicator turns green and makes a long beep Enter 1234 The indicator turns green and makes a long beep Press to exit The indicator turns green and makes a long beep Press to exit The indicator turns green and makes a long beep Note The default administrator passwor...

Page 6: ...ngerprint Press Enter new existed user ID Press finger three times or swipe the card once The indicator turns green and makes a long beep Press to continue registering editing The indicator turns green and makes a long beep Press to exit Note Enter user ID to add new user If the user ID already exists the device defaults to edit the user After registering a fingerprint successfully the indicator t...

Page 7: ... door opens only if the entered password matches with one of the 8 passwords The initial eight passwords for opening the door are set to 0 Deleting One User Press 2 The indicator turns green and makes a long beep Press to exit Enter user ID fingerprint swipe user card The indicator turns green and makes a long beep Verify administrator fingerprint The indicator turns green and makes a long beep Pr...

Page 8: ... are as follows Authentication Mode Value Description PW 1 Only password verification RF 2 Only RF card verification FP 3 Only fingerprint verification FP PW RF 4 fingerprint or password or RF Card verification RF PW 5 RF Card and password verification swipe card before entering password FP PW 6 fingerprint and password verification fingerprinting before entering password The door sensor has three...

Page 9: ...he alarm will not be triggered if the alarm switch is set to OFF status Press 0 1 Press to exit Verify administrator fingerprint Press Configure the alarm setting 0 enable 1 disable Configuring Administrator Authentication Alarm If the administrator fails in authentication in 3 attempts Administrator Authentication Alarm will be triggered No authentication can be made within 20 seconds The default...

Page 10: ... When the door is not closed well after the set time period the Door Sensor Alarm will generate an alarm signal to alert the users Press 0 4 Press to exit Verify administrator fingerprint Press Configure the door sensor delay range 1s 254s Note Values greater than 254 are considered invalid The indicator turns red and makes four short beeps When an alarm is triggered the device interior alarm will...

Page 11: ...nable Administrator Authentication Alarm enable Tamper Alarm enable Door Sensor Delay 10s Technical Specifications Fingerprint Collector SilkID Fingerprint Reader Key Type Touch key User Capacity 500 Fingerprint Capacity 500 Card Capacity 500 Access Control Function Unlocking Alarm Lock driver time length Alarm Function Tamper Alarm Failed Authentication Alarm Door Sensor Alarm Doorbell External w...

Page 12: ...11 ZK Building Wuhe Road Gangtou Bantian Buji Town Longgang District Shenzhen China 518129 Tel 86 755 89602345 Fax 86 755 89602394 www zkteco com Copyright 2019 ZKTECO CO LTD All rights reserved ...

Reviews: