SA40
User Manual
P a g e
| 10
Copyright©2021 ZKTECO CO., LTD. All rights reserved.
based users state.
(4)
When the deletion card is directly wiped, it enters the batch deleting card-
based users state.
Addition card
This is used to add user cards.
Deletion card
This is used to delete user cards.
User Categories
3.3
Category
Description
Card-based user
This category of users can open the door only by swiping the card.
Password-based user
This category of users can open the door only by entering the password.
Card-and-password
user
This category of users can open the door only by both swiping the card and
entering the password.
Wiring Definition
3.4
Access Control Mode Wiring
Red
DC 12V
Black
GND
Blue
NC (normally close)
Orange
COM (common)
Gray
NO (normally open)
Purple
SEN (door sensor)
Yellow
BUT (exit button)
Green
BELL+ (doorbell)
White
BELL- (doorbell)
4
Operations
When the operation is successful, the green indicator is on. When the operation failed, the blue indicator is
on.
1. Restore Factory Settings
Before performing any operations on a new all-in-one access control device, you must restore its factory
settings to initialize the device. To restore its factory settings, make a short circuit between pins 1 and 2, or
between pins 2 and 3 of the 3-pin connector (next to the relay) on the device board, and then power on
the device.