background image

SA40

 

 

 

 

 

 

 

    

User Manual 

P a g e

 | 14 

 

Copyright©2021 ZKTECO CO., LTD.  All rights reserved. 

2)

 

Card-and-password users: Press *#administrator password

6

swipe the card

 new password of 4-

6 digits# 

For example: *#

1234

6

swipe the card

123456 # 

Note: You can perform operations consecutively in administrator state and 

press * to exit the state

15. Set Door Opening Delay Time 

Press *#administrator password

7

1

enter the delay time# 

For example: *#

1234

7

1

3s# 

Note: The door opening delay time is 0-60s. The default value is 3s and the maximum value is 60s. 

16. Set Key Backlight 

Press*#administrator password

7

5

0/1/2 (0: normally off; 1: normally on; 2: the backlight is off when 

you touch the key) 

For example: *#

1234

7

5

0/1/2 

17. Set Indicator 

Press *#administrator password

7

6

0/1 (0: off; 1: on) 

For example: *#

1234

7

6

0/1 

18. Set Door Sensor Mode 

Press *#administrator password

7

4

0/1 (0: NC; 1: NO) 

For example: *#

1234

7

4

0/1 

19. Set Door Sensor Alarm Delay Time 

Press *#administrator password

7

7

enter the alarm delay time# 

For example: *#

1234

7

7

15# 

Note: The door sensor alarm delay time is 0-255s. The default value is 15s. 

20. Set Main Alarm Switch 

In standby mode, you can enable or disable the door sensor alarm or the alarm for pressing a key by 
mistake through shortcut operations. 

1)

 

Enable the alarms: Directly swipe the addition card for three times to enable the door sensor alarm and 
the alarm for pressing a key by mistake. 

2)

 

Disable the alarms: Directly swipe the deletion card for three times to disable the door sensor alarm 
and the alarm for pressing a key by mistake. 
 

Summary of Contents for SA40

Page 1: ...read the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only For fur...

Page 2: ...design and that the said personnel have received thorough training in operating and maintaining the machine unit equipment It is further essential for the safe operation of the machine unit equipment...

Page 3: ...unit equipment and such amendments shall not give any right to claim any compensation or damages under any circumstances ZKTeco shall in no way be responsible i in case the machine unit equipment malf...

Page 4: ...ndent research and development of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication f...

Page 5: ...ion Button or key names for devices For example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi level menus are sepa...

Page 6: ...TD All rights reserved Table of Contents 1 INSTALLATION DIAGRAMS 6 2 WIRING 6 3 BASIC CONCEPTS 9 DESCRIPTION OF KEYS 9 3 1 CARD CATEGORIES 9 3 2 USER CATEGORIES 10 3 3 WIRING DEFINITION 10 3 4 4 OPERA...

Page 7: ...R107 diode is randomly provided Do not reverse its positive and negative poles If an extension cable needs to be connected between the all in one device and the controller we recommend that you use a...

Page 8: ...1 2 The device and the lock do not share the power supply as shown in Figure 1 2 Note ULOCK 12 V and I IDEVICE ILOCK Or ULOCK 12 V Or the lock is far from the device Figure 1 2 I indicates the output...

Page 9: ...connected directly to the main board The operating current is equal to or less than 200mA and the standby current is equal to or less than 150mA The power supply can work after its positive and negati...

Page 10: ...ard 1 The installation card is the first card that is swiped after initialization 2 When the installation card is swiped once it enters the card adding mode If you swipe a user card this card is added...

Page 11: ...door only by both swiping the card and entering the password Wiring Definition 3 4 Access Control Mode Wiring Red DC 12V Black GND Blue NC normally close Orange COM common Gray NO normally open Purple...

Page 12: ...tate 4 Set General Door Opening Password Press administrator password 9 enter a password of 4 6 digits For example 1234 9 123456 Note The default administrator password is 1234 and the default general...

Page 13: ...assword must contain 4 6 digits 2 After a password based user is added you can continue to enter the user password to consecutively add password based users and press to exit the state 10 Add a Card a...

Page 14: ...cally You can press to exit the state 12 Delete All Users You can delete all users by using two methods 1 Press administrator password 5 For example 1234 5 2 In standby state swipe the administrator c...

Page 15: ...r example 1234 7 5 0 1 2 17 Set Indicator Press administrator password 7 6 0 1 0 off 1 on For example 1234 7 6 0 1 18 Set Door Sensor Mode Press administrator password 7 4 0 1 0 NC 1 NO For example 12...

Page 16: ...e times and no operation is performed 1 minute later the number of pressing a key by mistake allowed is resumed to five times 23 Restore Default Settings You can restore the default settings of the ac...

Page 17: ...rrect 3 Check whether the access control device is in the correct mode Failed to read the card 1 Check whether the card category is correct or whether the card is damaged 2 Check whether the external...

Page 18: ...ZKTeco Industrial Park No 32 188 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2021 ZKTECO CO LTD All Rights Reserved...