Page 6 of 20 

804721- CS_ChillTap Sparkling 09.16 v1.00

2.1

 

- Ventilation 

Proper air circulation must be provided for all Chilled models. The system will operate correctly only if the recommended air 
gaps are achieved during Installation. The minimum requirement is for a 50mm air gap either side and 300mm above of the 
undersink unit. 

It is important that the 4mm door buffers (For all installations ) are fitted to the inside edge of the cupboard door to allow 
sufficient air circulation inside the cupboard. (See the diagram below).

•  When installing air flow ducts, the following tools will be required:

•  Jigsaw and 12mm Drill

•  Keyhole or Wall Board saw.

Section 2 

Ventilation

50 min.

50 min.

200

min.

382

280

333

Ø 105

Clearance
Envelope

Vent pipe

(Blocked off)

Mains Cold water
isolation valve

240 - 230V,
50Hz GPO

CO

2

cylinder with

fixed 300kPa reguator

Inlet Vent

Carbonation
adjustable
flow valve

435

Clearance
Envelope

4 min,

Bufer Pad
Clear Gap

Summary of Contents for ChillTap 804721

Page 1: ...Zip ChillTap Sparkling Residential Filtered chilled still and chilled sparkling water Affix Model Number Label Here 804721 804721 09 16 v1 0...

Page 2: ...ct the gas hose 9 3 4 Test for gas leaks 9 Section 4 Undersink unit installation 10 John Guest J G fittings 10 4 1 Chiller Installation 11 4 2 Hose and Tube connections 11 4 3 Mains Connection 12 4 4...

Page 3: ...supply connection with isolating valve inside the cupboard is within reach of the braided hoses and positioned so that the connection point and the stop cock will not be obstructed when the undersink...

Page 4: ...safety For products sold in Europe this appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowled...

Page 5: ...el and rubber washers from the base of the carafe filler leaving the rubber sealing ring O ring in place Fit the carafe filler and seal to the sink oriented so both the operating levers are easily acc...

Page 6: ...m door buffers For all installations are fitted to the inside edge of the cupboard door to allow sufficient air circulation inside the cupboard See the diagram below When installing air flow ducts the...

Page 7: ...se applications where the cupboard space temperature is near 35 C or higher the inlet vent See Item B below and silicon buffers need to be fitted If the airflow is still insufficient to maintain norma...

Page 8: ...k out and cut the air inlet and door outlet holes as shown 2 Ensure the air inlet vent and air outlet vent are positioned at opposite ends of the same cupboard space 3 Fit the inlet vent as shown and...

Page 9: ...the gas bottle can stand before securing to the wall Due to regulatory requirements the gas bottle must be stored securely and in an upright position 3 2 Connect the regulator Make sure the regulator...

Page 10: ...nection The joint will need to be resealed and tested again Clean away the soapy residue and tighten or refit the leaking connection Make sure the regulator is turned off when tightening or refitting...

Page 11: ...n On Off Switch General instructions for John Guest connections NOTE Ensure all John Guest tube ends are cut clean and square John Guest JG fittings If caps are removed to allow lifting handles to be...

Page 12: ...braided hose from the isolation valve to the top of the undersink unit marked MAINS IN 4 4 Chilled Still Connection Remove the plug fitted into the connection marked Still Outlet by first depressing t...

Page 13: ...be running for approximately 1 second before filling your glass or bottle The same is applicable if still water is dispensed prior to dispensing sparkling water Undersink Unit Installation 4 Connect...

Page 14: ...ely 5 minutes the compressor and fan will stop as the chiller has reached its normal operating temperature To achieve an optimal level of carbonation it is beneficial to purge the carbonation vessel a...

Page 15: ...flow rate 2 To adjust the flow rate rotate the adjustment screw anti clockwise to increase the flow and clockwise to decrease the flow see FIG 3 Use 1 4 or 1 2 turn increments 3 To measure the flow ra...

Page 16: ...lter will click or lock into place 5 Turn the still water tap on 6 Turn on the water supply to the unit Allow 7 5 litres to flow from the outlet 7 Turn off the still water lever 8 Turn on the power su...

Page 17: ...rst and then the power supply 9 Wait 20 seconds and then turn on the sparkling lever and wait for water to start to come through 10 Dispense some sparkling water from the tap Perform a taste test Serv...

Page 18: ...2 regulator valve is open Replace empty CO2 gas bottle Contact local Zip Service Provider See warm drinks symptom below or allow chilled system time to recover Purge system as described on page 15 Gas...

Page 19: ...ld be checked regularly at least monthly and dusted or vacuumed Sanitising the Carbonation unit may be required when the quality of sparkling water deteriorates Please contact your local Zip service p...

Page 20: ...y is one of continuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of the finished good...

Reviews: