Zip Celsius HydroTap G4 range Installation Instructions Manual Download Page 8

Page 8 of 28 

   802149UK   Celsius residential - Installation instructions -Jan 2016 v2.03

Major components and accessories

Accessories

Description

Scale filter

installation kit 

*ZT200G4

Filter not included.

Replacement  

internal 0.2 micron 

filter 

ZT402

1 X

 CO

2

 gas cylinder  

ZT400

Recommended  

water block      

HE45004

Parts supplied

Description

Tap options

1 x

Celsius Arc

Boiling or chilled or 

chilled sparkling tap

1 x

Celsius Cube

Boiling or chilled or 

chilled sparkling tap

Command-Centre

TM

 and components

Vent kit 

(C ,CS models only)

1 x Outlet vent (C)

2 x Outlet vent (CS)

1 x Inlet vent

1 x

Command-Centre

TM

 

with air and water 

filters

1  x  Mains  water            

connection hose

1 x T-piece & 

adaptor

1 x User guide and 

1 x Quick start 

guide

1 x Installation 

instruction

1 x 

CO

2

 gas cylinder 

assembly

(CS models only)

801599 - HydroTap User Guide - Nov 2013 UK - V1.05

Page 1 of 20

ZIP HydroTap

User Guide

®

Tap Operation...................(Pages 2-5)

LCD Screen & Menu .......(Pages 6-18)

Maintenance.................... (Pages 18-20)

Date of Installation.........

Affix Model Number Label 

Here

 801599

BC160/125G4

BC240/175G4

BCH160/125G4

BCH240/175G4

AV160/125G4

AN160/125G4

AV240/175G4

AN240/175G4

801600 - Zip Quick Start Guide - October 2013 - V1.06

Parts Supplied

Description

Parts Supplied

Description

1 off

Hydrotap Tap

and hoses

Duct kit

1x Air Duct

1 x Mounting 

plate

1 off

Undersink Unit 

with air and water-

filter

Vent kit

1 x Kickboard 

louvre

1 x Door vent 

louvre

1 x front vent grill

1 x Restrictaflow 

valve and Tee 

piece for Mixer 

Taps

1 off

HydroTap 

Booster heater 

and hoses

(Supplied with 

240/175 models)

1 off Mains water 

connection hose

QUICK START GUIDE

Note: This quick start guide must be read in conjunction with 

the main installation and user instructions 

• 

Before proceeding, read the installation and user instructions

• 

Check all the components are present and correct.

• 

Check that you have all the necessary tools

• 

Ensure the underbench can support the product weight when full of water,                                   

(Check the specifications in the main book and allow an extra 5-8kg when full. )

Before installing ensure the following have been provided at 

the installation site:

• 

Sufficient space in the cupboard to install all of the undersink units in accordance 

with these Installation Instructions. Refer to technical specification for dimensions. If 

required, make allowance for a booster heater. (Refer to the main book, for detailed 

installation instructions). 

• 

A potable water supply connection with isolating valve inside the cupboard within 

reach of the flexible braided hose and positioned so that the connection point and the 

stop cock will not be obstructed when all the undersink units are installed. 

• 

For Zip HydroTap 160/125 &160/175 models, a 220-240Vac, 10A GPO will be 

required. For Zip HydroTap 240/175 models, two 220-240Vac, 10A GPOs will be 

required. (One GPO is for the Zip HydroTap and the other for the Booster heater).                                                                                                                         

NOTE: Check the cable lengths and outlet positions before proceeding. 

• 

A potable cold water supply with a minimum working pressure of 172kPa and a 

maximum working pressure of 700kPa connected via an isolation valve. 

• 

For the mains pressure All-IN-ONE, both a hot and cold water supply will be required.

• 

The undersink appliances must be mounted in upright positions as shown in the 

diagrams. 

IMPORTANT!

  Do not proceed with the installation if these 

requirements are not met.

STEP 1- 

Prepare and fit the Taps

Hole positioning: 

Position the tap such that it dispenses into 

the sink bowl with ample clearance for a cup or tea pot. Alternatively, 

the tap could be mounted away from the sink using a Zip Font, avail-

able as an accessory.

Apply a light smearing of silicon sealant 

on the underside of the upper spacer to 

ensure a watertight fi t.

For HydroTap and Mixer taps 

cut a 35mm hole in the bench / sink top.

BENCH TOP

Ø35mm

HydroTap Tap

Mixer Tap 

4-in-1

 

(If required)

NUT

LOWER RUBBER 

WASHER

UPPER 

RUBBER 

WASHER

WASHER

BRAIDED 

HOSE x 3

UPPER RUB-

BER WASHER

LOWER RUB-

BER WASHER

WASHER

NUT

White Hose

Ext. Mains

Blue band

Mixer  IN

Red band

Mixer Out 

O-RING

BASE 

BLOCK  

SPIDER

BASE 

BLOCK 

NUT

USB 

CABLE

ALL 

THREAD 

ROD

NOTE: feed each of 

the tubes and elec-

trical cable evenly in 

between the legs of 

the BASE BLOCK 

SPIDER.

All-In-One Tap 

(If required)

For AIO mains and vented Taps

Cut a 50mm hole in the bench / sink top.

NOTE: make sure the tap location will allow the nozzle to drain into the sink. 

SINK TOP

50mm

ALL THREAD 

ROD

STAINLESS 

STEEL  

WASHER

SPIDER 

CLAMP

NUT

BLACK 

PLASTIC 

SPACER

NOTE: feed each of the three tubes and 

electrical cable evenly in between the legs of 

the SPIDER CLAMP when installing. 

Fit the 

STAINLESS STEEL           

WASHER, 

SPIDER CLAMP, 

AND 6mm NUT.  

6mm 

NUT

SPIDER 

CLAMP

Stainless 

washer

Black plastic 

spacer

35mm dia hole

Sink

O-RING

SINK TOP

Fit the O-ring to the underside of the AIO tap 

then pass all hoses through the 50mm hole. 

Chiller 

connection 

BLUE

From 

Mixer OUT

 to Tap - Vented version only

Boiler 

connection 

RED

Blue ring on 

RHS mains IN to

       

Mixer IN

White ring

on LHS to 

Mains in

Tap

O ring Base

Clear tube to Vent

*ZT200G4 kit to fit filters FL1100

Summary of Contents for Celsius HydroTap G4 range

Page 1: ...HydroTap G4 Celsius Installation instructions Filtered boiling chilled and chilled sparkling drinking water with unfiltered mixed hot and cold water for residential kitchens Affix model number label h...

Page 2: ...rs a complete range of features and functionality to suit the customer s needs Celsius Arc range Celsius Cube range Boiling mixed hot cold These taps are directly compatible with the G4 residential Co...

Page 3: ...ation Section 2 Ventilation 2 1 Ventilation on all models 14 Step 3 Mount the external filter softener if required 3 1 Mounting the filter head and cartridge installation 15 3 2 Cartridge installation...

Page 4: ...under counter cupboard supporting the Command CentreTM is adequate for the total weight of Command CentreTM when full of water Before commissioning Check the Command CentreTM has been installed correc...

Page 5: ...to chill the water for chilled models and an immersion heating element to boil the water for boiling models Chilled sparkling models utilise a CO2 gas cylinder to carbonate the chilled water Boiling...

Page 6: ...the font pedestal ensure the tap body is located so the tap outlet safely dispenses into the sink bowl area Lifting Take care when lifting the Command CentreTM which may exceed safe lifting limits If...

Page 7: ...s of nature Due to the process of continuous improvement Zip reserves the right to change details mentioned in this manual without notice Visit www zipwater com uk to ensure you have the latest copy C...

Page 8: ...on with isolating valve inside the cupboard within reach of the flexible braided hose and positioned so that the connection point and the stop cock will not be obstructed when all the undersink units...

Page 9: ...will continue to be dispensed after the rated capacity has been used although this may affect the dispense temperature Min Max water supply pressure Celsius Boiling mixed hot cold 0 17 MPa 1 7 bar 0...

Page 10: ...ecification page 9 for power ratings Note Check all cable and hose lengths against inlet outlet positions before proceeding See section 5 for general layout A potable water supply connection with isol...

Page 11: ...nut runner not supplied for fixing the tap assembly Hole size and positioning Position the tap such that it dispenses into the sink bowl with ample clearance for a jug cup or tea pot 35mm hole require...

Page 12: ...ation will allow the tap spout to drain into the sink 35mm Fit the brass and rubber washers and secure with brass nut Installation instructions 35mm hole 1 2 Chilled and sparkling mixed hot cold tap i...

Page 13: ...d hot cold tap installation Nut Brass washer Lower rubber washer Upper rubber washer USB lead Chilled blue or Boiling red pipe depending on model Vent clear pipe Mains hot and cold braided hoses Vent...

Page 14: ...drawn in from the bottom of the cupboard and expelled through the top of the cupboard The outlet vent A should be towards the top of the door position A1 or side of the cupboard position A2 Where pos...

Page 15: ...a quarter turn anticlockwise until cartridge comes to a complete stop Cartridge installation is complete Note The following instructions to flush the filter must be undertaken AFTER commissioning of...

Page 16: ...O2 may be discharged from the connection to the regulator as the cylinder and the regulator are be assembled together Any CO2 released will be cold Screw on the regulator to stop this leakage Note The...

Page 17: ...lied with a sponge or with a brush cover all of the gas joints with a liberal amount of suds Stage 2 1 Turn the gas ON 2 Adjust the pressure to between 2 7 3 0 bar 3 Inspect the joint for leaks 4 If a...

Page 18: ...ion B if a scale filter is fitted before flushing the scale filter as described on page 22 5 2 Braided hose fitting Install the mains water braided hoses to the Command CentreTM before locating in pla...

Page 19: ...G OUT BYPASS IN VENT BYPASS OUT 280mm 50mm 50mm 535mm COLD isolation valve not supplied Clearance Envelope Note All plastic pipes silicon tubes must be trimmed to size They must have a constant fall t...

Page 20: ...lves not supplied 280mm 50mm 50mm 535mm Male to male adaptor to T piece supplied T piece supplied Clearance Envelope Note All plastic pipes silicon tubes must be trimmed to size They must have a const...

Page 21: ...lope Note Mains hose length is 750mm Electrical power cable length is 3 0m nom Position the Command CentreTM according to the hose and cable lengths supplied 5 3 Chilled sparkling and mixed hot cold A...

Page 22: ...he filter flush mode is in operation Open the filter access door on the front of the HydroTap G4 Celsius and the filter cartridge will be exposed Located to the rear right hand side of the cartridge i...

Page 23: ...ished close the stop cock then press STOP to end filter flush mode Press NEXT for the boiling calibration screen boiling models OPEN Position CLOSED Position ON OFF Filter flush menu Stop cock operati...

Page 24: ...ck Ventilation Call Zip Service Condenser Sensor Open Internal fault Check ventilation Call Zip service Heater Fuse Driver Fault Internal fault Call Zip Service Heater Driver Fault No hot water Call Z...

Page 25: ...o be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for collection and recycling of unwanted electrical and electronic...

Page 26: ...or This warranty does not cover damage resulting from non operation of the appliance the use of non authorised parts or consequential damage to any other goods furnishings or property No warranty appl...

Page 27: ...802149UK Celsius residential Installation instructions Jan 2016 v2 03 Page 27 of 28 Notes...

Page 28: ...Aust Pty Ltd Zip products described in this publication are manufactured under one or more of the following patents AU675601 AU637412 AU635979 GB0422305 GB2065848 US4354049 US5103859 US5099825 and SA2...

Reviews: