1. Description of the appliance

As soon as you open the hot water tap, the instantaneous water heater switches on 

auto ma ti cally. When the tap is  closed, the appliance automatically switches off. 

The E-convenience instant water heater DCX Next is a electronically controlled pres-

sure-resistant instantaneous water heater for an efficient water supply to one or more 

tap outlets .
Its electronic control regulates the power consumption depending on the selected 

outlet temperature, the respective inlet temperature and the flow rate, thus reaching 

the set temperature exactly to the degree and keeping it constant in case of water 

pressure fluctuations . The outlet temperature can be set to 35 °C, 38 °C, 42 °C, 48 °C 

or 55 °C using the central sensor key .
In case of a low feed temperature and a high flow rate at the same time, it could hap-

pen that the preset outlet temperature is not reached which is due to the fact that the 

appliance exceeded its capacity . The outlet temperature can be raised by reducing the 

water flow at the tap .
It is possible to use the instantaneous water heater in combination with an external 

load shedding relay for electronically controlled instantaneous water heaters (refer to 

installing instructions) .

2. Environment and recycling

Operation instruction

Note: Carefully read the enclosed safety instructions through in full before the appliance 

is installed, put into service and used and follow them in the further steps and during use!

 This product was manufactured climate neutrally according to Scope 1 + 2 . We recom-

mend the purchase of 100% green electricity to make the operation climate neutral as 

well . 

Disposal of old products: 

Your product was manufactured from high-quality, reusable 

materials and components . Products marked with the crossed-out wheeled bin sym-

bol must be disposed of separately from household waste at the end of their service 

life . Therefore, take this product to us as the manufacturer or to one of the municipal 

collection points that recycle used electronic devices . This proper disposal serves to 

protect the environment and prevents possible harmful effects on humans and the 

environment that could result from improper handling of the products at the end of 

their service life . For more detailed information on disposal, please contact your near-

est collection point or recycling centre or your local council .

Business customers:

 If you wish to discard equipment, please contact your dealer or 

supplier for further information .
For disposal outside Germany, please also observe the local regulations and laws .

Summary of Contents for InLine DCX Next

Page 1: ...nual Modelnumber DCXNext Electronicallycontrolledinstantaneouswaterheaters 1 Installation instructions user manual 9120 34379 v1 20 Okt 2022 ZIP DCX Next Technical support Tel 0345 6 005 005 email ser...

Page 2: ...2013 814 2013 8 6 Warranty 9 Installation instruction 1 Overview 10 2 Technical specifications 11 3 Dimensions 11 4 Installation 12 Installation site 12 Mounting accessories 12 Installing the wall bra...

Page 3: ...gs and taps may be very hot when the appliance has been in use for some time The values stated on the rating plate must be observed In case of malfunction disconnect the mains power supply immediately...

Page 4: ...re of 0 2 to 0 4MPa 2 4bar The appli ance must not be subjected to pressure exceeding 1 0MPa 10bar The appliance must only be used when correctly installed and in perfect working order The appliance m...

Page 5: ...n with an external load shedding relay for electronically controlled instantaneous water heaters refer to installing instructions 2 Environment and recycling Operation instruction Note Carefully read...

Page 6: ...econds to open the info mode After ten seconds all LEDs light up once briefly and then switch off again immediately to confirm that the info mode is active The device status is displayed via the LEDs...

Page 7: ...m inadvertently running dry Nevertheless the appliance must be vented before using it for the first time Each time the appliance is emptied e g after work on the plumbing system if there is a risk of...

Page 8: ...r product information listed elsewhere may result in different test conditions The power consumption was determined in compliance with standardized measurement method based on EU guidelines The real e...

Page 9: ...r the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting from n...

Page 10: ...afety pressure cut out SDB Connecting terminal Frame Cold water connection Fine filter Water splash protection sleeve DCX Next hood Non return valve Flow sensor Thermal sensor Thermal sensor Outlet pi...

Page 11: ...ype pressure resistant pressureless Heating system Bare wire heating system IES 15 C Required specific water resistance Specific electrical conductivity 1100 cm 90mS m Inlet temperature 30 C Flow rate...

Page 12: ...ly with water connections left The appliance complies with protection type IP25 and may therefore be installed in protection zone 1 according to VDE 0100 part 701 IEC 60364 7 In order to avoid thermal...

Page 13: ...according to the template and drill them using a 6mm drill Insert the included dowels 3 To open the appliance pull down the faceplate and unscrew the main hood screw Lift the hood carefully remove the...

Page 14: ...ht cor rections are possible by carefully bending the threaded rod of the wall bracket However it must be possible to screw on the water connection pipes of the appli ance without applying force 2 Scr...

Page 15: ...low reducer D into the hot water connection piece The hot water and cold water connectors must then be screwed into the inch union nut of the appliance inlet and outlet pipe together with the inch sea...

Page 16: ...water heaters IN 82250 can be connected to phase con ductor L2 To avoid possible jitter of the load shedding relay caused by low power consumption low temperature set point and low water flow rate th...

Page 17: ...nal to the upper foot Affix the connecting terminal again 6 Strip the individual wires of the connecting cable and plug them in the connecting terminals according to the wiring diagram The appliance m...

Page 18: ...lect the maximum allowable power rating depending on the local situation To do this take the auxiliary tool A from the holder on the electronics cover and turn the switch to the desired value 2 Put th...

Page 19: ...must not be pinched or squeezed Then switch on the power again e g via activating the fuses Maintenance work must only be conducted by an authorised professional 8 Maintenance work Cleaning and replac...

Page 20: ...0 34379 v1 20 Okt 2022 ZIP DCX Next Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk www zipwater co uk ZipWaterUK TrafalgarHouse Rash sGreen Dereham Norfolk N...

Reviews: