Installation instructions & user manual

 

9120-34379 v1.20 Okt 2022 - ZIP DCX Next

Technical support 

 

Tel: 0345 6 005 005 email: [email protected]  www.zipwater.co.uk

4. Installation

The following regulations must be observed:
•  e.g. VDE 0100
•  EN 806
•  Installation must comply with all statutory regulations, as well as those of the local 

electricity and water supply companies.

•  The rating plate and technical specifications
•  Only intact and appropriate tools must be used

Installation site

•  Appliance must only be installed in frost-free rooms . Never expose appliance to 

frost .

•  The Appliance must be wall mounted and has to be installed with water connectors 

downward or alternative transversely with water connections left .

•  The appliance complies with protection type IP25 and may therefore be installed in 

protection zone 1 according to VDE 0100 part 701 (IEC 60364-7) .

•  In order to avoid thermal losses, the distance between the instantaneous water 

heater and the tap connection should be as small as possible .

•  The appliance must be accessible for maintenance work .
•  Plastic pipes may only be used if they conform to DIN 16893, Series 2 . 
•  The specific resistance of the water must be at least 1100 Ω cm at 15 °C . The specific 

resistance can be asked for with your water distribution company .

•  When considering the location of the heater, consideration should be given to the 

safe and visible disposal of any water resulting from leaks and seepage . This is par-

ticularly relevant when the heater is located in a cupboard or any concealed loca-

tion . For guidance please call Zip on 0345 6 005 005 .

Summary of Contents for InLine DCX Next

Page 1: ...nual Modelnumber DCXNext Electronicallycontrolledinstantaneouswaterheaters 1 Installation instructions user manual 9120 34379 v1 20 Okt 2022 ZIP DCX Next Technical support Tel 0345 6 005 005 email ser...

Page 2: ...2013 814 2013 8 6 Warranty 9 Installation instruction 1 Overview 10 2 Technical specifications 11 3 Dimensions 11 4 Installation 12 Installation site 12 Mounting accessories 12 Installing the wall bra...

Page 3: ...gs and taps may be very hot when the appliance has been in use for some time The values stated on the rating plate must be observed In case of malfunction disconnect the mains power supply immediately...

Page 4: ...re of 0 2 to 0 4MPa 2 4bar The appli ance must not be subjected to pressure exceeding 1 0MPa 10bar The appliance must only be used when correctly installed and in perfect working order The appliance m...

Page 5: ...n with an external load shedding relay for electronically controlled instantaneous water heaters refer to installing instructions 2 Environment and recycling Operation instruction Note Carefully read...

Page 6: ...econds to open the info mode After ten seconds all LEDs light up once briefly and then switch off again immediately to confirm that the info mode is active The device status is displayed via the LEDs...

Page 7: ...m inadvertently running dry Nevertheless the appliance must be vented before using it for the first time Each time the appliance is emptied e g after work on the plumbing system if there is a risk of...

Page 8: ...r product information listed elsewhere may result in different test conditions The power consumption was determined in compliance with standardized measurement method based on EU guidelines The real e...

Page 9: ...r the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting from n...

Page 10: ...afety pressure cut out SDB Connecting terminal Frame Cold water connection Fine filter Water splash protection sleeve DCX Next hood Non return valve Flow sensor Thermal sensor Thermal sensor Outlet pi...

Page 11: ...ype pressure resistant pressureless Heating system Bare wire heating system IES 15 C Required specific water resistance Specific electrical conductivity 1100 cm 90mS m Inlet temperature 30 C Flow rate...

Page 12: ...ly with water connections left The appliance complies with protection type IP25 and may therefore be installed in protection zone 1 according to VDE 0100 part 701 IEC 60364 7 In order to avoid thermal...

Page 13: ...according to the template and drill them using a 6mm drill Insert the included dowels 3 To open the appliance pull down the faceplate and unscrew the main hood screw Lift the hood carefully remove the...

Page 14: ...ht cor rections are possible by carefully bending the threaded rod of the wall bracket However it must be possible to screw on the water connection pipes of the appli ance without applying force 2 Scr...

Page 15: ...low reducer D into the hot water connection piece The hot water and cold water connectors must then be screwed into the inch union nut of the appliance inlet and outlet pipe together with the inch sea...

Page 16: ...water heaters IN 82250 can be connected to phase con ductor L2 To avoid possible jitter of the load shedding relay caused by low power consumption low temperature set point and low water flow rate th...

Page 17: ...nal to the upper foot Affix the connecting terminal again 6 Strip the individual wires of the connecting cable and plug them in the connecting terminals according to the wiring diagram The appliance m...

Page 18: ...lect the maximum allowable power rating depending on the local situation To do this take the auxiliary tool A from the holder on the electronics cover and turn the switch to the desired value 2 Put th...

Page 19: ...must not be pinched or squeezed Then switch on the power again e g via activating the fuses Maintenance work must only be conducted by an authorised professional 8 Maintenance work Cleaning and replac...

Page 20: ...0 34379 v1 20 Okt 2022 ZIP DCX Next Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk www zipwater co uk ZipWaterUK TrafalgarHouse Rash sGreen Dereham Norfolk N...

Reviews: