6. Electrical connection
Wiring diagram
1 . Electronic circuitry
2 . Heating element
3 . Safety pressure cut-out
4 . Connecting terminal
5 . Safety thermal cut-out
Load shedding relay
If further three-phase appliances are connected, a load shedding relay designed for
electronic instantaneous water heaters (IN . 82250) can be connected to phase con-
ductor L2 .
To avoid possible jitter of the load shedding relay caused by low power consumption
(low temperature set point and low water flow rate) the “Load-shedding-mode” can be
activated as followed:
• Disconnect the appliance from the power supply (e .g . by switching of the fuses)
• Take the jumper off the power electronics and change to position “
1
” (see picture) .
• Put the appliance into operation again
Pos. OFF
Pos. 1
Structural prerequisites
• The appliance must be installed via a permanent connection . Heater must be
earthed!
• The electric wiring should not be injured . After mounting, the wiring must not be
direct accessible .
• An all-pole disconnecting device (e .g . via fuses) with a contact opening width of at
least 3 mm per pole should be provided at the installation end .
• To protect the appliance, a fuse element must be fitted with a tripping current com-
mensurate with the nominal current of the appliance .