15
Installation instructions & user manual
9120-34379 v1.20 Okt 2022 - ZIP DCX Next
Technical support
Tel: 0345 6 005 005 email: [email protected] www.zipwater.co.uk
5. Direct connection
Note: Fasten the screw nuts with caution, to avoid damage to the valves or the piping
system.
For direct connection, the two ½ inch screw-in nipples and the ½ inch seals must be
screwed into the ½ inch union nuts of the hot-water and cold-water connectors . The
two ½ inch caps of the side outlets of the hot-water and cold-water connectors must
be removed and screwed onto the open end of the screw-in nipples . Put the water
flow reducer “
D
” into the hot water connection piece . The hot-water and cold-water
connectors must then be screwed into the ⅜ inch union nut of the appliance inlet and
outlet pipe, together with the ⅜ inch seals .
For direct connection, it may be advisable to mount the appliance at a distance as illus-
trated alongside, using the spacer sleeves supplied . The two fixing holes near the lower
pipe connections are also to be professionally fixed with 6 mm dowels and screws .
The flared end of the pipes must be screwed into the ½ inch side outlets of the hot-
water and cold-water connectors with ½ inch union nuts and ½ inch seals . The holes
required for the pipes must then be opened of the housing with the aid of a blunt
implement .
In case of direct connection please note: Put the strainer into the cold water connec-
tion!
D