Page 6 of 28
804052US v1.27 06.21 CS75 Install Instructions
Important Safety Instructions
This manual contains important safety, Installation instructions for the Zip HydroTap.
Safety
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.
For products sold in Europe, this appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they
have been given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be
made by children without supervision.
Refrigerant
The Zip HydroTap Command Center contains R134A refrigerant under pressure. Maintenance of the
refrigeration unit must be carried out by an accredited service provider or qualified refrigeration technician.
Qualifications
If the power cable is damaged it must be repaired only by a qualified technician. To avoid hazards, all
Installation procedures must be carried out by a suitably qualified tradesperson. The power cable and power
outlet must be in a safe visible position for connection.
Venting
Ensure the faucet body is located so the faucet outlet safely dispenses into the sink bowl area.
Lifting
Take care when lifting the Zip HydroTap Command Center. Some units may exceed safe lifting limits. If you
feel this is beyond your personal capabilities, please seek assistance with the lift. The weights of the units are
marked on the packaging. Do not lift the Command Center by the front cover or any connections at the top
rear of the unit. Refer to the technical specifications for the weight of your product.
Airflow
The ambient operating temperatures, when installed in a cabinet, must be between 5 - 35°C (41 - 95ºF). The
system will operate satisfactorily only with proper air ventilation. The recommended air gaps of 50mm (2”) on
each side, and 200mm (8”) above must be provided. See section 2 for correct ventilation details.
Positioning
It is important to ensure the Command Center is positioned in an accessible area close to the floor level. The
Command Center must have its base mounted in a horizontal position with all inlets and outlets facing up.
The Faucet must be located above the Command Center. See Section 4 for details.
!