   804052US v1.27 06.21 CS75 Install Instructions

Warranty

Limited Warranty- Zip Products

What Does This Warranty Cover?

Culligan International Company, d/b/a Zip Water, (hereinafter “Zip”), warrants to the original purchaser (the “Zip 

Customer”) of the Zip product (the “Zip Product”), so long as the Zip Customer purchased the Zip Product from an 

authorized Zip dealer (“Authorized Zip Dealer”), that this Zip Product, including any of its original accessories, is free of 

defects in material and workmanship, subject to the terms and conditions set forth herein. This Limited Warranty covers 

parts and labor, except as set forth in this Limited Warranty

Where Is This Limited Warranty Valid?

This Limited Warranty is only applicable if the Zip Product was installed in the United States of America (“USA”).

What Is Required to Request Warranty Service?

All three of the following are required before warranty service will be performed:  (1) Verification of the purchase date; 

(2) Verification that the Zip Product was purchased from an Authorized Zip Dealer; and (3) Verification that the Zip 

Product at issue was installed by an authorized Zip service technician or an approved Zip service provider.

When Does the Limited Warranty Expire?
One (1) Year Limited Warranty

 - Any warranty claims for Zip Products must be received by Zip within 15 months 

from the date of purchase or within 12 months from date of installation.  This warranty guarantees that if any part 

should fail within 15 months from date of purchase or within 12 months from the date of installation, except as detailed 

below, Zip or its authorized service provider will repair or replace the Zip Product.  Determination to repair or replace 

will be in Zip’s sole discretion. Repair or replacement services will be at no cost to the Zip Customer, provided that:
a)  the Zip Product is installed and used strictly in accordance with the instructions supplied; and
b)  all service under the One (1) Year Limited Warranty is carried out only by an authorized Zip service technician or 

an approved Zip service provider.
This warranty includes both parts and labor.

Extended Two (2) Year Limited Warranty

 – In addition to the One (1) year Limited Warranty described above, 

the Zip Customer can opt to extend the Zip Product warranty by one (1) year, making the total Limited Warranty period 

two (2) years. In order to extend the warranty to two (2) years, the Zip Customer must register their product with Zip. 

This extended two (2) year Limited Warranty is subject to the same conditions as provided above in clauses a) and b).

How To Register?

Zip Products must be registered online at https://www.us.zipwater.com 

What If Repair Is Impossible?

If Zip determines that the warranted repair of any Zip Product is impossible, the Zip Product shall, at Zip’s discretion, 

either be replaced or refunded. 

What Is Not Covered by This Limited Warranty?
This Limited Warranty does not cover:

•  Damage or defects caused by, or resulting from, repairs, service, conversion or alterations to the Zip Product 

or any of its parts and accessories which have been performed by service centers or repairmen not authorized by 

Zip; damage or defects caused by negligence, improper installation (when not installed by an authorized Zip service 

provider), accident, abuse, misuse, power interruptions, power surges, unsuitable water conditions, floods, natural 

disasters, or force majeure; or improper maintenance of the Zip Product or its parts or accessories.
•  Ordinary wear and tear.

Summary of Contents for CS 75

Page 1: ...804052US v1 27 06 21 CS75 Install Instructions Page 1 of 28 CS 75 Zip HydroTap Installation and Operating Instructions Scan QR Code to download the latest version of this document English French...

Page 2: ...customer s needs For ease of installation it is recommended to fit the faucet before installing the Command Center The installation procedure for each of the faucets is detailed in the Faucet Installa...

Page 3: ...for All Models 11 2 2 Cabinet Air Circulation 12 STEP 3 Fit the CO2 Gas cylinder Section 3 CO2 Cylinder and regulator 3 1 Secure the cylinder mounting 14 3 2 Connect the regulator 14 3 3 Connect the...

Page 4: ...appliance rating plate and ensure correct power is available for the appliance G Check the under counter cabinet supporting the appliance is adequate for the total weight of the appliance when full of...

Page 5: ...the chilled water Chilled water dispensed is factory set to 6 10 C 43 50 F These units are NOT designed to be used for sanitary fixtures The CO2 bottle and the water filter require periodic replacemen...

Page 6: ...cian Qualifications If the power cable is damaged it must be repaired only by a qualified technician To avoid hazards all Installation procedures must be carried out by a suitably qualified tradespers...

Page 7: ...ver be located near or cleaned with water jets 7 Zip HydroTaps are not to be exposed to the elements of nature 8 Due to the process of continuous improvement Zip reserves the right to change details m...

Page 8: ...on hose Vent Kit 1x Inlet vent 1x Outlet vent 9 x Screws 1x Installation Instructions this book and 1x User Guide 1x CO2 gas cylinder regulator assy Major components and accessories Accessories Descri...

Page 9: ...faucet CS75 Classic XX CS75 ARC XX and CS75 CUBE XX have been tested and certified by WQA against NSF ANSI Standard 372 for low lead requirement and against NSF ANSI Standard 42 and NSF ANSI Stand ar...

Page 10: ...oses and positioned so that the connection point and the stop cock will not be obstructed when the Command Centers are installed A cold water supply with a working pressure range of 250 700 kPa 37 100...

Page 11: ...and a 12mm Drill Keyhole or Wall Board saw 2 1 Ventilation for All Models Proper air circulation must be provided for all models The system will operate correctly only if the recommended air gaps are...

Page 12: ...or higher the inlet vent See Item B below and silicone buffers need to be fitted If the airflow is still insufficient to maintain normal operating temperatures then the inlet vent and door outlet vent...

Page 13: ...t and door outlet holes as shown 2 Ensure the air inlet vent and air outlet vent are positioned at opposite ends of the same cabinet space 3 Fit the inlet vent as shown and secure with 5 screws 4 If r...

Page 14: ...the cabinet Make sure the gas bottle can stand before securing to the wall Due to regulatory requirements the gas bottle must be stored securely and in an upright position 3 2 Connect the regulator Ma...

Page 15: ...h the product Connect the power lead to the HydroTap and connect the plug into the electrical power outlet ensuring both ends are securely engaged to reduce the risk of overheating John Guest fittings...

Page 16: ...refitting the leaking connection Refit the gas bottle to the hook and loop strap and secure the bottle in an upright position NOTE Care must be taken when working with high pressure carbon dioxide IMP...

Page 17: ...Sparkling Note Mains hose length is 750mm 30 Plug and Cord length is 1800mm 70 Position the Command Center close to the outlet faucet within reach of the hose and cord lengths supplied Note Note The h...

Page 18: ...a language After commissioning the system may be customised by selecting further options in Section G Settings within the User Manual 5 1 Select the Language Initial Commissioning screen Language sel...

Page 19: ...ure 5 After one hour repeat step 2 6 Dispense 2 liters gallon of sparkling water from the sparkling outlet Repeat the 2 liters gallon dispense until the water is clear 7 Check that the water is clear...

Page 20: ...ckflow of gas and or water out of the internal carbonator In addition to the HydroTap s integral Backflow prevention Some authorities require additional Backflow Prevention to be installed to comply w...

Page 21: ...ion Call Zip Service Condenser sensor Open Internal fault Check ventilation Call Zip service Compressor driver fault No chilled water Call Zip Service Condenser overtemp Blocked air filter Remove bloc...

Page 22: ...n or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Red...

Page 23: ...or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduc...

Page 24: ...or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduc...

Page 25: ...t for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requirement Average Reducti...

Page 26: ...place the Zip Product Determination to repair or replace will be in Zip s sole discretion Repair or replacement services will be at no cost to the Zip Customer provided that a the Zip Product is insta...

Page 27: ...Servicer Provider who performed the warranty service the purchase date a detailed description of the problem and the address and phone number at which the Zip Customer can be reached Zip is committed...

Page 28: ...Standard 42 and NSF ANSI Standard 53 This will deliver the required bacteriostatic effect and the reduction of aesthetic chlorine taste odor nominal particulate Class I 0 5 m to 1 m cyst and lead as v...

Reviews: