804052US v1.27 06.21 CS75 Install Instructions
Page 15 of 28
Section 4
Command Center Installation
4.2
Hose and tube fitting
•
Remove all caps from the top of the Command Center
•
Fit the foam insulation to the Blue and to the White tubes after trimming them to length
•
Install the mains water braided hoses to the Command Center before locating the unit in place.
NOTE: Do not overtighten
NOTE:
Before installation, determine whether a water softener or an external filter is required.
4.1
Electrical power supply
Warning:
HydroTap models are available for either 110-120V, 60Hz OR 230V, 50Hz AC
installations. Ensure the electrical power supply at the installation site is suitable for your HydroTap.
Use only the power lead supplied with the product. Connect the power lead to the HydroTap and
connect the plug into the electrical power outlet, ensuring both ends are securely engaged to reduce the risk
of overheating.
John Guest
fittings
(Insertion and removal)
Be careful when cutting the poly tube so that there are no rough
edges and that the tube is not distorted.
1. Use a sharp knife to ensure the tube has a clean, straight
edge. Do not cut at an angle.
2. Remove any swarf or unwanted material.
3. Push the tube into the John Guest fitting making sure all
connections to the John Guest fittings are pushed in past
the “O” ring to full depth, at least 1
5mm (⅝”).
4. Check for a good joint by pulling back on the tube. If the
tube comes out, of the fitting, repeat the above step.
5. To remove the tube, press the collet into the fitting and at
the same time pull back on the tube.
Power lead for 110-120V, 60Hz ONLY
(NEMA 5-15 / IEC C19)
Power lead for 230V, 50Hz ONLY
(NEMA 6-15 / IEC C13)