Fault Finding 

(cont.)

Problem

Possible cause

Solution

The “Pressure” indicator

Flow rate too low (ILX only).

Increase flow pressure

lights, water remains cold.

(ILX only).

Water flow rate is less

Depends on the heater.

Check technical

than expected.

specifications.

Minimum dynamic water.

pressure is below ·8 bar

Outlet fitting dirty or calcified.

Clean tap fitting or

shower head.

Filter dirty or calcified.

Clean or renew the filter.

Unsuitable tap.

Contact customer service.

The hot water is not

Electronics faulty (ILX only).

Reset fuse. In case of

hot enough.

repeated failures, contact

customer service (ILX only).

Flow rate is too high (winter?). Reduce the water flow slightly.

Heating element defect.

Contact customer service.

Flow and temperature of

The water pressure or the

Stabilise flow pressure, check

the hot water varies.

voltage is varying (ILH only).

supply voltage (ILH only).

Temperature and

Cold water is being

Only hot water can be

pressure vary.

added (ILX only).

delivered to within one 

degree (ILX only).

Technical Support 

If a fault in your appliance cannot be rectified with the aid of this table, please 
contact Zip Heaters who will either assist you directly or put you in touch with
a service engineer in your area. Always specify the appliance model and serial
numbers. Use this chart to record the number during installation.

*Model No.

*Serial No.

Date of Installation

Zip Heaters (UK) Ltd

Tel: 0870 608 8888      Fax: 01362 692448

e-mail: [email protected]

8                                                             LH6, ILH9, ILX6, ILX9 & ILX12 Installation Instructions

Summary of Contents for ILH6

Page 1: ...l Connection 5 Operation 5 6 Saving Energy 6 Routine Preventative Maintenance 6 7 Fault Finding 7 8 Technical Support 8 Spare Parts 9 These instructions should be read carefully and understood before...

Page 2: ...ectly fitted to comply with the requirements of the United Kingdom Water Regulations Byelaws Scotland The product therefore is listed under the WRAS Water Regulations Advisory Scheme Water Fitting and...

Page 3: ...tenance of this appliance must only be conducted by a competent installer who will then be responsible for adherence to applicable standards and installation regulations The ILH6 9 and ILX6 9 12 are f...

Page 4: ...Suitable for cold water up to 30 C Water connection 1 2 B S P for concealed or surface mounting Required spec water resistance 15_C 1100 cm 15 C ILX 12 only Net weight 2 2kg Dimensions h x w x d 33cm...

Page 5: ...ubber seal supplied and introduce the connecting lead When using a flexible cable it must be secured with the cable clamp provided on the rear of the appliance back plate 6 Screw the appliance into po...

Page 6: ...Completely fill the appliance with water before switching on the power supply 3 Explain to the user how the instantaneous water heater works and leave these instructions for their reference Operation...

Page 7: ...shown by the flashing Power indicator At high incoming water temperatures the power is automatically switched off to avoid producing excessively hot water This is shown by the Overheat indicator If th...

Page 8: ...indicator Circuit breaker Have the fault rectified does not light and the tripped and reset water is cold Flow pressure switch is Increase flow pressure not working ILH only ILH only Safety thermal c...

Page 9: ...slightly Heating element defect Contact customer service Flow and temperature of The water pressure or the Stabilise flow pressure check the hot water varies voltage is varying ILH only supply voltage...

Page 10: ...essure switch 9 Flow reducer 11 Cable seal 12 Pilot lamps 13 Set of small spare parts Washers filter screws and micro switch 14 Cold water inlet ILX Item Description 1 1 2 b s p connector 2 Flow rate...

Reviews: