Spare Parts

ILH 

Layout of appliance and spare parts

When ordering, please always specify the appliance model and serial number!

Item Description

1

1/2” 

b.s.p. connector

2

Temperature monitor

3

3

Flow valve with filter

4

Heating element

5

Safety thermal cut-out

6

Appliance front cover

7

Connection terminal

8

Differential pressure switch

9

Flow reducer

11 Cable seal
12 Pilot lamps
13 Set of small spare parts (Washers,

filter, screws and micro-switch)

14 Cold water inlet

ILX

Item Description

1

1/2” 

b.s.p. connector

2  Flow rate adjustment

with filter

3 Heating element
4 Display panel
5 Safety thermal

cut-out (STB)

6 Appliance front cover
7 Connection terminal
8 Electronic board
9 Flow sensor

10 Cold water inlet
11 Cable seal
12 Set of small spare

parts (Washers, filter,
screws and micro-switch)

ILH6, ILH9, ILX6, ILX9 & ILX12 Installation Instructions                                                           9  

Summary of Contents for ILH6

Page 1: ...l Connection 5 Operation 5 6 Saving Energy 6 Routine Preventative Maintenance 6 7 Fault Finding 7 8 Technical Support 8 Spare Parts 9 These instructions should be read carefully and understood before...

Page 2: ...ectly fitted to comply with the requirements of the United Kingdom Water Regulations Byelaws Scotland The product therefore is listed under the WRAS Water Regulations Advisory Scheme Water Fitting and...

Page 3: ...tenance of this appliance must only be conducted by a competent installer who will then be responsible for adherence to applicable standards and installation regulations The ILH6 9 and ILX6 9 12 are f...

Page 4: ...Suitable for cold water up to 30 C Water connection 1 2 B S P for concealed or surface mounting Required spec water resistance 15_C 1100 cm 15 C ILX 12 only Net weight 2 2kg Dimensions h x w x d 33cm...

Page 5: ...ubber seal supplied and introduce the connecting lead When using a flexible cable it must be secured with the cable clamp provided on the rear of the appliance back plate 6 Screw the appliance into po...

Page 6: ...Completely fill the appliance with water before switching on the power supply 3 Explain to the user how the instantaneous water heater works and leave these instructions for their reference Operation...

Page 7: ...shown by the flashing Power indicator At high incoming water temperatures the power is automatically switched off to avoid producing excessively hot water This is shown by the Overheat indicator If th...

Page 8: ...indicator Circuit breaker Have the fault rectified does not light and the tripped and reset water is cold Flow pressure switch is Increase flow pressure not working ILH only ILH only Safety thermal c...

Page 9: ...slightly Heating element defect Contact customer service Flow and temperature of The water pressure or the Stabilise flow pressure check the hot water varies voltage is varying ILH only supply voltage...

Page 10: ...essure switch 9 Flow reducer 11 Cable seal 12 Pilot lamps 13 Set of small spare parts Washers filter screws and micro switch 14 Cold water inlet ILX Item Description 1 1 2 b s p connector 2 Flow rate...

Reviews: