background image

Best performance is achieved at a flow pressure of 

3 bar, the rated 

pressure of 6 bar (10 bar ILX12) must not be exceeded as failure to 
observe this will invalidate the warranty.

• Hot and cold water pipes should be WRAS approved and of copper or 

plastic construction.

Installing the appliance

Plumbing

1 An isolating valve must be installed in the cold

water supply line to the heater.

2 Before connecting the water supply to the

appliance flush the pipe by running a  quantity of
water into a bucket.

3 Remove the front cover by unscrewing the locking 

screw behind the small lid.

4 Locate and break out the required holes and cable 

inlets. Use the back-plate as a template to locate
the drilling positions and drill them with a 6mm bit,
ensuring there are no hidden cables or pipe-work.

5  Insert the rubber seal supplied and introduce the

connecting lead. When using a flexible cable it
must be secured, with the cable clamp provided,
on the rear of the appliance back-plate.

6 Screw the appliance into position using the

enclosed rawl plugs and screws.

7  Install the appliance vertically as per diagram. The

inlet and outlet are marked with arrows.

8 The water connections are designed for concealed or surface-mounted 

installation and must be carefully sealed with a little PTFE tape when
screwed into the wall connections.

9 The front cover must be cleanly parted at the specified points for surface-

mounted installation or for direct connection to the pipes of the sanitary
fitting using the optional piping kit ZL001.

10 Open the water supply to the appliance and the tap to check all 

connections for leaks.

11 Open and close the hot water tap several times until no more air emerges

from the tap and all air has been evacuated from the heater.

4                                                             LH6, ILH9, ILX6, ILX9 & ILX12 Installation Instructions

Summary of Contents for ILH6

Page 1: ...l Connection 5 Operation 5 6 Saving Energy 6 Routine Preventative Maintenance 6 7 Fault Finding 7 8 Technical Support 8 Spare Parts 9 These instructions should be read carefully and understood before...

Page 2: ...ectly fitted to comply with the requirements of the United Kingdom Water Regulations Byelaws Scotland The product therefore is listed under the WRAS Water Regulations Advisory Scheme Water Fitting and...

Page 3: ...tenance of this appliance must only be conducted by a competent installer who will then be responsible for adherence to applicable standards and installation regulations The ILH6 9 and ILX6 9 12 are f...

Page 4: ...Suitable for cold water up to 30 C Water connection 1 2 B S P for concealed or surface mounting Required spec water resistance 15_C 1100 cm 15 C ILX 12 only Net weight 2 2kg Dimensions h x w x d 33cm...

Page 5: ...ubber seal supplied and introduce the connecting lead When using a flexible cable it must be secured with the cable clamp provided on the rear of the appliance back plate 6 Screw the appliance into po...

Page 6: ...Completely fill the appliance with water before switching on the power supply 3 Explain to the user how the instantaneous water heater works and leave these instructions for their reference Operation...

Page 7: ...shown by the flashing Power indicator At high incoming water temperatures the power is automatically switched off to avoid producing excessively hot water This is shown by the Overheat indicator If th...

Page 8: ...indicator Circuit breaker Have the fault rectified does not light and the tripped and reset water is cold Flow pressure switch is Increase flow pressure not working ILH only ILH only Safety thermal c...

Page 9: ...slightly Heating element defect Contact customer service Flow and temperature of The water pressure or the Stabilise flow pressure check the hot water varies voltage is varying ILH only supply voltage...

Page 10: ...essure switch 9 Flow reducer 11 Cable seal 12 Pilot lamps 13 Set of small spare parts Washers filter screws and micro switch 14 Cold water inlet ILX Item Description 1 1 2 b s p connector 2 Flow rate...