Specification
Product Type
ILH6
ILH9
ILX6
ILX9
ILX12
Capacity:
0.2 litre
Pressure type ( rating pressure):
6 bar
10 bar
Heating system:
Tubular heater
Bare wire
Nominal rating:
6.6 kW/230V
8.8 kW/230V
6.6 kW/230V
8.8 kW/230V
13.5 kW
Rated voltage (50/60) Hz
1/NPE220-240V 1/NPE220-240V 1/NPE220-240V 1/NPE220-240V
3/PE 400V
Rated current
28.7A
38.3A
28.7A
38.3A
19.5A
Max. temperature increase:
At nominal rating & flow rate of 4 l/min
24°C
32°C
24°C
32°C
48°C
flow rate of 6 l/min
16°C
21°C
16°C
21°C
32°C
flow rate of 8 l/min
12°C
16°C
12°C
16°C
24°C
flow rate of 10 l/min
9°C
13°C
9°C
13°C
19°C
Switch-on flow rate:
2.9l/min
3.5l/min
2l / min
Temperature pre-setting:
N/A
35 - 55°C
Minimum dynamic water pressure
·8 bar
N/A
Suitable for cold water up to:
30°C
Water connection:
1/2
” B.S.P. for concealed or surface mounting
Required spec. water resistance @15_C:
≥
1100
Ω
cm@15°C (ILX 12 only)
Net weight:
2.2kg
Dimensions (h x w x d):
33cm x 21cm x 9cm
Class / Degree of protection (IEC 529):
1 / IP25
Approvals:
See paragraph 2
Installation
This appliance is not intended for use with thermostatic blending valves.
The following must be observed:
• The appliance must be installed in accordance with current IEE regulations.
• Note the specifications on the rating plate and the technical specifications.
• Do not proceed if any stage of installation is unclear.
Installation site
• The installation site must be free from frost at all times.
• The appliance complies with protection type IP25.
• In order to minimise thermal losses, the distance between the heater and the
outlet tap should be as short as possible (<2m).
ILH6, ILH9, ILX6, ILX9 & ILX12 Installation Instructions 3