Setup Water cooling Circuit 

14 

 

 

 

Page 19 

 

 

Emptying the water 

cooling circuit

 

 

To empty the water cooling circuit the user has to press the button in the 

configuration menu. After that, a message occurs that instructs the user to plug in the 

tube and set up a collection container to empty the cooling circuit. (See figure below). 

 

 

 

 

After that step a message occurs that shows that the pumping process. 

 

 

 

 

If the process is finished a message appears that shows the user that the whole 

system is empty. 

 

 

 

 

 

Summary of Contents for Z Wave Q

Page 1: ...User Manual ZWaveQ USA...

Page 2: ......

Page 3: ...Illustrations Front of the device Fig 1 Encoder Handpiece...

Page 4: ...he SysCart Fig 2 Switches Connector sockets 1 Socket for mains cable 2 Main fuse 3 Identification plate 4 Socket for footswitch Fig 3 Switches Connector 1 Socket for handpiece 2 Identification plate 3...

Page 5: ...s Screens and Displays Fig 4 Start Screen 1 Settings 2 Protocols direct activation of application screen Fig 5 Therapy Screen 1 Pulse Energy 2 Frequency 3 Start button 4 Treatment Menu 5 Pulse Mode 1...

Page 6: ...ns Screens and Displays Fig 6 Maintenance Screen 1 Handpiece Information 2 Footswitch Connection 3 Fill Empty the water cooling circuit 4 Test Handpiece Button 5 General Settings 6 Maintenance Button...

Page 7: ...ories Slim Handpiece Accessories Aesthetic handpiece Accessories Slim handpiece Aesthetic handpiece Silicone cap 15mm Silicon cap 39mm Applicator head 15mm Applicator head 39 mm Filling funnel with ho...

Page 8: ...his symbol indicates Attention with regard to possible damage of the device Application Part Typ BF Instructions for use Follow instructions for use Serial number Article number Manufacturer Date of m...

Page 9: ...ater evacuation Do not reuse If used more than once cross infection may occur The transport package shall not be exposed to sunlight Symbol to indicate the maximum and minimum temperature limits at wh...

Page 10: ...ar of the Device Screens Displays Explanation of Symbols Page 1 Intended Purpose 1 2 Side Effects 2 3 Application Information 3 4 Warnings 4 5 Device Setup 5 6 Self Test 6 7 Basic Settings 7 8 Operati...

Page 11: ...tup Water cooling Circuit 17 15 Error Messages Troubleshooting Disposal 21 16 Manufacturer s EMC declaration 25 Valid for ZWaveQ devices This instructions for use is an integral part of the device It...

Page 12: ...area Local infections in the treatment area Application in the area of malignant benign tumors Application directly on cartilage surfaces or in the area of the small facet joints of the spine Applica...

Page 13: ...Side Effects 2 Page 2 Treatments with ZWaveQ can occasionally lead to dermatitis petechiae haematoma swelling or pain...

Page 14: ...ion Do not place the device adjacent to heat sources heating hot mud products sauna etc and leave a gap of at least 20 inches between the device and a wall to allow for adequate ventilation and coolin...

Page 15: ...ymbol Do not lean on the device The silicone protection cap 39mm for the Aesthetic handpiece must be inspected for wear and tear after each treatment Simultaneous connection of the patient to a high f...

Page 16: ...left front of the monitor Filling the water circuit See Chapter 14 Switch off the device The unit is switched off via the main switch 6 To disconnect the unit completely all pole from the mains supply...

Page 17: ...rmed as described below This test should be performed monthly or if there are any doubts about the viability of the device Note Before performing the functional test ensure that the handpiece and foot...

Page 18: ...alphanumeric keyboard for entering a welcome message on the start up screen Activation of the button with the green arrow saves the entered text Activation of the button with the red cross takes you...

Page 19: ...ootswitch The information about the connected footswitch is shown in this display 3 Water cooling circuit Gives the user the possibility to empty and fill the water cooling circuit 4 Pulse Counter Her...

Page 20: ...esponding row 5 Number of pulses Display of the preselected number of pulses and the currently emitted pulses as well as the total number of emitted pulses if the total number of emitted pulses is not...

Page 21: ...e is available for the application Changing the applicator heads To change the applicator head for each specific handpiece hold the handpiece with one hand and unscrew the applicator head from the han...

Page 22: ...ction on the skin lotion provided as accessory should be applied Due to the weight of the handpiece firmly pressing down on application area point is usually not necessary The handpiece is placed and...

Page 23: ...port Temperature 10 50 C Humidity 20 80 relative humidity without condensation Air pressure 700 1060 hPa Storage Temperature 10 C 50 C Humidity 20 80 relative humidity without condensation Air pressur...

Page 24: ...ll cables can be disinfected using disinfectant wipes To do so use a commercially available alcohol free disinfectant for metal and plastic with bactericidal viricidal and fungicidal properties Observ...

Page 25: ...fection manual Tools Vessel e g kidney dish Commercially available alcohol free disinfectant for metal and plastic with bactericidal virucidal and fungicidal properties We recommend that disinfection...

Page 26: ...ories Art no 5556 5555 Handpiece H2O Slim Optional Handpiece H2O Aesthetic 93133540 93133511 Applicator head 39mm Applicator head 15 mm 6525450701 95135120 6825451101 80000226 9325450201 10 Silicone p...

Page 27: ...n units are provided by the manufacturer Anyone who contrary to these specifications combines devices and thus operates a medical system does so at its own risk Whoever combines the devices and thus o...

Page 28: ...ly trained personnel the device is not operated in hazardous areas and or a combustive atmosphere the device is disconnected immediately from the power supply upon the penetration of liquid b The devi...

Page 29: ...ton to fill the water cooling circuit the following steps have to be done The message gives the user the instruction to plug in the filling tube Then the user has to fill in the distilled water and mo...

Page 30: ...in the configuration menu After that a message occurs that instructs the user to plug in the tube and set up a collection container to empty the cooling circuit See figure below After that step a mess...

Page 31: ...ater left in the system Disconnect the handpiece To separate the handpiece the user has to press the right button in the configuration menu Then a message occurs that shows the user how to position th...

Page 32: ...message occurs and gives the user the instructions to repeat the process If the process was successful a message occurs to show the user that the handpiece can now be disconnected Attention The handpi...

Page 33: ...r tip and inside the handpiece area Then hold the handpiece without applicator head with the opening facing downwards and produce some pulses maximum 10 with 2 or 5 Hz frequency at the lowest energy l...

Page 34: ...First check the power supply completely for possible errors If the fault persists contact the service representative customer service immediately Error message SD card On the SD card the user defined...

Page 35: ...e above To access the pump open the front flap and unlock the four screws in the front Please connect the pump with the socket for water filling in the rear of the SysCart in Figure 3 After connecting...

Page 36: ...department in Irvine Service department Distributor Zimmer MedizinSystems 3 Goodyear Suite B Irvine CA 92618 Phone 800 327 3576 Fax 949 727 2154 www zimmerusa com info zimmerusa com Manufacturer Zimme...

Page 37: ...Otherwise degradation of the performance of this equipment could result The device was tested for RF immunity only at selected frequencies Nearby transients at other frequencies may result in degraded...

Page 38: ...nvironment Surges in accordance with IEC 6100 4 5 Line to Line 0 5 kV 1 kV 0 5 kV 1 kV Surges in accordance with IEC 6100 4 5 Line to Earth 0 5 kV 1 kV 2 kV 0 5 kV 1 kV 2 kV Voltage dips in accordance...

Page 39: ...ence is possible Radiated RF EM fields according IEC 61000 4 3 3 V m 80 MHz 2 7 GHz 80 AM to 1 kHz 3 V m 80 MHz 2 7 GHz 80 AM to 1 kHz Table 4 Electromagnetic immunity to HF radio communication equipm...

Page 40: ...A 10 102 902 MW 1019 I Version 2 1 I Modifications reserved Zimmer MedizinSystems 3 Goodyear Suite B Irvine CA 92618 800 327 3576 949 727 2154 fax www zimmerusa com info zimmerusa com ZWaveQ User Manu...

Reviews: