25
10.2.17 Mounting LWR50F-15-04-A and LWR50F-15-05-A
Activation is done via SCM or a commercially available IO-Link master with Port Class B.
pin Color
Function
Explanation
4
2
1
8
12
9
6
3
7
5
11
10
M12, 12-pin Connector straight
1
Brown
+ 24 V DC sensor
IO-Link communication supply
2
Blue
+ 24 V DC actuator
Actuator supply voltage
3
White
GND sensor
0 V DC sensor supply voltage
4
Green
C/Q
IO-Link communication
5
-
-
-
6
-
-
-
7
-
-
-
8
Gray
GND actuator
0 V DC actuator supply voltage
9
-
-
-
10
-
-
-
11
-
-
-
12
-
-
-
10.2.18 Mounting LWR50F-16-01-A
pin Color
Function
Explanation
1
2
3
4
M8, 4-pin Connector/bracket
1
-
-
-
2
White
Output 2
Inside signal
3
-
-
-
4
Black
Output 1
Outside signal
pin Color
Function
Explanation
1
2
3
4
M8, 4-pin Connector/bracket
1
Brown
24 V DC
24 V DC supply voltage
2
White
Input 1
Inward move command
3
Blue
GND
0 V DC supply voltage
4
Black
Input 2
Outward move command
The inputs of the product are configured for PNP outputs of the control system.
10.2.19 Mounting LWR50F-17-01-A
pin Color
Function
Explanation
4
2
1
6
8
7
5
3
M8, 8-pin Connector/bracket
1
-
-
-
2
Brown
Output 3
Connect signal: 24 V DC if MATCH gripper is
coupled.
3
Green
Output 2
Inside signal
4
Yellow
Output 1
Outside signal
5
Gray
24 V DC
24 V DC supply voltage
6
Pink
Input 1
Inward move command
7
Blue
Input 2
Outward move command
8
Red
GND
0 V DC supply voltage
The inputs of the product are configured for PNP outputs of the control system.
INSTALLATION AND OPERATION INSTRUCTIONS:
LWR50F
DDOC01074 / f
EN / 2023-06-05
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com