16
6.2 Functional safety
For the overall safety of the function, all three components (MATCH robot module, MATCH gripper and MATCH storage
station) must be taken into account.
The safety function that ensures secure locking between the MATCH robot module and MATCH gripper of the product is
implemented via two redundant action channels that consist of a mechanical locking and springs.
Technical supplementary safety measures (sensors) provide a high degree of diagnostic coverage. The product can thus be
classified into control category 3 in accordance with Chapter 6.2.6 of DIN EN ISO 13849-1. According to Figure 5,
Chapter 4.5.4 of the specified standard, the PL d can be achieved with this product.
Fault elimination in accordance with DIN EN ISO 13849-2, Annex A, Table A2 and A3 for the helical compression springs
used can be given.
7 Technical data
INFORMATION
►
You can find the information in the technical data sheet on our website.
This data varies within the series, depending on the specific design.
►
Please contact Zimmer Customer Service if you have any questions.
8 Accessories/scope of delivery
INFORMATION
If any accessories not sold or authorized by Zimmer GmbH are used, the function of the product cannot be
guaranteed. Zimmer GmbH accessories are specifically tailored to the individual products.
►
For optional accessories and those included in the scope of delivery, refer to our website.
9 Transportation/storage/preservation
►
Store the product in its original packaging.
►
If the product has already been installed on the superordinate machine unit, care must be taken during transport to
ensure that no unexpected movements can occur.
►
Before commissioning the product and after transport, check all power and communication connections as well as
all mechanical connections.
►
If the product is stored for an extended period, the following points are to be observed:
►
Keep the storage location as dust-free and dry as possible.
►
Avoid temperature fluctuations/observe and adhere to the temperature range.
►
Avoid wind/drafts/water condensation formation.
►
Cover the product with a weatherproof, tear-resistant foil to prevent dust.
►
Pack the product and do not expose it to direct sunlight during storage.
►
Clean all components. There must be no soiling left on the components.
►
Visually inspect all components.
►
Remove all foreign substances.
►
Close electrical connections using suitable covers.
INSTALLATION AND OPERATING INSTRUCTIONS:
LWR50F-01-03-A
DDOC01360 / -
EN / 2022-05-09
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com
Summary of Contents for MATCH LWR50F-01-03-A