Exhaust air fan Aero_aH 100 with integrated room and cellar dehumidification control
1019-1-0002
Handbuch 31.01.2021_JUSC_Aero_aH100|
16
4.2.
Intended use
The device is only intended for domestic use and
similar purposes.
The unit is designed for dehumidification of cellars,
storage rooms, showrooms, offices, changing
rooms and similar rooms up to a size of
approximately 25 m
2
.
Operation is only permitted for:
•
Permanent installation inside buildings
•
Installation on a wall or ceiling
•
Air ducting via shaft or pipe
•
Electrical flush-mounted connection
Full functionality is only achieved with the included
outdoor climate sensor (closing flap with integrated
outdoor climate sensor).
ATTENTION
:
Restricted use in case
of structural defects.
In case of structural defects, water
often penetrates basement rooms via floors
and walls.
In such cases, the ventilation system Aero_aH
100 can be used as a supplement for basement
dehumidification. The unit supports brickwork
drying through controlled air exchange but
cannot achieve complete dehumidification by
itself.
ATTENTION:
Risk of damage to the
building fabric if ventilated
manually.
Excessive manual ventilation can lead to room
humidification when the outdoor humidity is
high. Therefore, it is essential to pay attention
to the duration of ventilation when using an
external switch.
4.3.
Forseeable misuse
ZILA does not assume any liability for damage
caused by improper use.
Do not use the unit under
any circumstances:
•
In individual ventilation systems according to
DIN18017-3
•
Near flammable materials, liquids or gases
•
For conveying chemicals, aggressive gases or
vapours
•
In explosive atmospheres
•
In outdoor areas
4.4.
Technical data
Technical specifications can be found in the product
specific data sheet on our website
.
4.5.
Operating and environmental
conditions
•
The
medium’s
maximum temperature
permitted is + 40 °C.
•
When
operating
with
air-dependent
fireplaces, sufficient supply air must be
provided.
•
The maximum pressure difference permitted
per flat is 4 Pa.
5.
Safety instructions
5.1.
General
•
Assembly and electrical connection
may only be undertaken by
electricians in accordance with
chapter 1.
•
Read these mounting and operating
instructions
carefully
before
commissioning.
•
Only connect unit to permanently
wired electrical installations with
NYM-O or NYM-J (3 x 1.5 mm² or 5 x
1.5
mm²)
cables.
Mains
disconnection device required with