57
ProBee-ZS10 User Guide Rev.1.1
device does not send a poll request to its parent coordinator or router within the poll
timeout, the end device is removed from the child table.
Execute
ATS51?<CR>
ATS51=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default
60
Range
0 – 4177920
7.4.2
S52
Description
Get/Set the sleepy end device poll period in milliseconds. Adaptive polling may allow
the sleepy end device to poll more rapidly for a short time when receiving RF data.
Execute
ATS52?<CR>
ATS52=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default
100
Range
0 - 10000
7.4.3
S53
Description
Get/Set the sleep duration in quarter seconds. An end-device sleeps at this time and
turns off radio every sleep cycle. If a node sleeps over poll timeout of parent node, the
device will be removed from the child table.
Execute
ATS53?<CR>
ATS53=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default
8
Range
0 – 16711680
7.4.4
S54
Description
Get/Set the standby timeout in seconds. When an end-device wakes up and polls with
the parent node, the node will wait for another data from the ZigBee network or from
the serial port for S54 before it goes to sleep mode again. If any serial or RF data is
sent or received, the timer will reset and wait for next again.
Execute
ATS54?<CR>
ATS54=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default
5
Range
0 – 10000