45
ProBee-ZS10 User Guide Rev.1.1
5.8.5
AT+FLOWCTRL or AT+UF
Description
Get/Set flow control status. (0: none, 1: software, 2: hardware flow control)
Execute
AT+FLOWCTRL?<CR>
AT+FLOWCTRL=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
2
Range
0 - 2
5.9
Security
5.9.1
AT+SECURITY or AT+SE
Description
Get/Set the security status. (0: turning security off, 1: on) Every node must be under
the same security level in the network.
Execute
AT+SECURITY?<CR>
AT+SECURITY=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
0
Range
0 - 1
5.9.2
AT+LINKKEY or AT+LK
Description
Get/Set the 128-bit link key. (0 or 0s: generate 128-bit random number)
Execute
AT+LINKKEY?<CR>
AT+LINKKEY=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
5.9.3
AT+NWKKEY or AT+NK
Description
Get/Set the 128-bit network key. (possible to set only for coordinator, 0 or 0s: generate
random 128-bit number)
Execute
AT+NWKKEY?<CR>
AT+NWKKEY=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
5.9.4
AT+UPDATEKEY or AT+UK
Description
Update the network key with a new generated key. (possible only for coordinator) It is
applied after 30s later because sending too quickly may cause a sleepy end-device to
miss the alternate encryption key and only get the switch key message, which means it
will be unable to change to the new network key.
Execute
AT+UPDATEKEY<CR>