55
ProBee-ZS10 User Guide Rev.1.1
Range
0 – 99
7.3.3
S33
Description
Get/Set the transmission timeout in milliseconds. If application-ACK is enabled, a
sender retransmits data packet after this time.
Execute
ATS33?<CR>
ATS33=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default
500
Range
0 – 10000
7.3.4
S34
Description
Get/Set the indirect transmission timeout in milliseconds. It is the maximum amount of
time that the MAC will hold a message for indirect transmission to a child.
Execute
ATS34?<CR>
ATS34=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default
7680
Range
0 – 30000
7.3.5
S35
Description
Get/Set the broadcast range. ZigBee specifies three different broadcast addresses that
reach different collections of nodes. Broadcasts are normally sent only to routers.
Broadcasts can also be forwarded to end devices, either all of them or only those that
do not sleep. Broadcasting to end devices is both significantly more resource-
intensive and significantly less reliable than broadcasting to routers.
0: send to all routers
1: send to all non-sleepy nodes
2: send to all nodes in the network
Execute
ATS35?<CR>
ATS35=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default
2
Range
0 – 2
7.3.6
S36
Description
Get/Set the maximum number of hops the message will be relayed. The message will
be delivered to all nodes within this number of hops of the sender. A value of zero is