Caution!  Temperature sensor terminals 

The pin connections of Sensors 1…6 (below) are not compatible with Sensors 7…12 (above). If a 3-wire-
technique sensor connected below is to be connected above, both external connections must be 
swapped.  
Temperature sensors must be connected to the plug-in terminals T11, T12, T13 etc. To ensure proper 
operation this plug-in terminals have gold-plated contacts. Do not use these plugs for other terminals. 

 

Caution!

 

The  sensor  inputs  and  the  RS485  interface  are  applied  to  the  same  electrical  potential  but  are 
galvanically isolated (2kV) for the auxiliary voltage. Take this into consideration during configuration. 

 
RS485 connection: 

Use RS485 Interface only with shielded wires. 
Large cable lengths may shift the potential ground and the transmission can be disturbed. 
Corrective measures can be galvanic separation or an additional ground wire. 
Max. allowed cable length is 1000m. 

 
 

Observe  the  maximum  temperature  permissible  when  installing  in  switching  cabinet.  Make  sure 
sufficient  space  to  other  equipment  or  heat  sources.  If  the  cooling  becomes  more  difficult  e.g. 
through  close  proximity  of  apparatus  with  elevated  surface  temperature  or  hindrance  of  the 
cooling air, the tolerable environmental temperature is diminishing. 

 

 

   

Before switching on make sure that the operational voltage Us of the 

 

 

 

type- plate and the mains voltage are the same.  

 

 

   

A circuit-breaker or switch must be situated within easy reach of the  

 

 

 

unit and fused. Installation excess current protection should be  

≤ 10 A.  

 
 

 

 

!

!

Summary of Contents for TR1200

Page 1: ...l illuminated Displays the value of the warmest sensor in the digital display 3 Digital display 3 digits red Display of sensor value Display of error codes e g 8Er98 4 Hindmost decimal point red OFF D...

Page 2: ...L S 2 Sensor 2 3 L S 3 Sensor 3 3 L S 4 Sensor 4 3 L S 5 Sensor 5 3 L S 6 Sensor 6 3 L S 7 Sensor 7 nc S 8 Sensor 8 nc S 9 Sensor 9 nc S10 Sensor 10 nc S11 Sensor 11 nc S12 Sensor 12 nc rel Rel Relay...

Page 3: ...ct condition To keep this condition observe the security instructions with the headline Attention written in the instructions manual Ignoring of the security instructions may lead to death physical in...

Page 4: ...figuration RS485 connection Use RS485 Interface only with shielded wires Large cable lengths may shift the potential ground and the transmission can be disturbed Corrective measures can be galvanic se...

Page 5: ...cluded in delivery Connection according to connection plan or type plate 6 Commissioning 6 1 Control chart Unit Pressing buttons Up Down simultaneously sets the values to the smallest one Code Reset P...

Page 6: ...Sensors 1 12 83 L8 3 conductor connection 8 nc8 No sensor connected 8rel8 Relay function 8bus 8 Menu item for configuring the RS485 interface 8Prt 8 Protocol RS485 interface 84858 RS485 protocol 8Mod...

Page 7: ...chnique Terminals of sensor 1 6 are not compatible to terminals sensor 7 12 Parameter configuration not allowed Code lock active The Code lock can be activated as a protection against manipulation of...

Page 8: ...vice address in menu item 8bus 8 8adr8 to 818 12 RTD half duplex operation mode 1x TR 1200 works like 2x TR 600 The TR 1200 transmits the data from Sensors 1 6 on request with address 1 and from Senso...

Reviews: