9.1.3
Protection rating
Component
Protection rating
motor
IP 42
Absolute encoder
IP 40
Brake (electrical)
IP 54
Brake (mechanical)
IP 10
Complete machine
IP 21
9.1.4
Ambient conditions
The user must ensure that the speci
fi
ed ambient conditions are observed.
Ambient temperature for operation
[
°
C]
0 to +40
Humidity
[%]
Maximum 95 / condensation not permitted
Installation height
[m above
sea]
Above 1000
Torque reduction by 1 % per 100 m or
On time reduction by 1.5 % per 100 m
Table 9-1-4
9.1.5
Brake
Brake type
RTW 1000
(information for each brake circuit)
Brake torque
[Nm]
1200
Operating voltage
[VDC]
207
Power
[W]
158
Electrical protection rating
IP 54
Mechanical protection rating
IP 10
9.1.5.1
Micro switch
Minimum switching capacity
[mA / V DC]
10 / 12
Maximum rating
[A / V AC]
3 / 250
Recommended rating
[mA / V DC]
10 - 50 / 24
Table 9-1-5-1
9.1.5.2
Inductive proximity switch
Operating voltage
V DC
10 bis 30
Rated operating current
mA DC
≤
150
Output functions
NC contact / gauge zero
Table 9-1-5-1
For further information refer to the
“
Appendix - Brake operating instructions - Assembly and adjust-
ment of the release monitor with inductive proximity switch
”
chapter.
Translation of the original operating instructions
ZAtop
–
model series SM210.60B/SM210.70B
Enclosure
A-TBA17_01-GB 2023/46 Index 008Part.-No. 01013389-GB (EU-BD 1014/1)
41/96