Figure 4-5-01 - Rope guard
"
"
The elevator machine is on the right and left
fi
tted with rope guard (1).
"
"
A 3rd rope retainer (2) is optionally available.
"
"
Set the rope guard to a distance of 2 - 3 mm from the ropes.
Rope guard adjustability
The elevator machine is equipped with a
fi
xed or adjustable rope guard depending on the angle of
contact.
Figure 4-5-02 - For wrap angle 180
°
.
Figure 4-5-03 - Adjustability on both sides
±
5
°
.
Normal wrap angles 175
°
- 185
°
.
Figure 4-5-04 - Adjustability on both sides + 5
°
/- 30
°
.
Normal wrap angles 150
°
- 185
°
.
Figure 4-5-05 - Adjustability on both sides + 5
°
/- 90
°
.
Normal wrap angles 90
°
- 185
°
.
Translation of the original operating instructions
ZAtop
–
model series SM210.60B/SM210.70B
Mechanical installation
A-TBA17_01-GB 2023/46 Index 008Part.-No. 01013389-GB (EU-BD 1014/1)