CAUTION!
Caution!
The internal 24 V power supply is provided solely for the digital inputs. Switching consumer load with
this voltage is prohibited!
Terminal assignment X-IN
•
You can con
fi
gure the inputs I1
…
I8 assignments. The con
fi
guration can be implemented by:
–
Presetting the used control system (assignment corresponding to the control requirements)
–
Free con
fi
guration
•
Implement con
fi
guration of the digital inputs in the
Control system\CONFIG
menu.
The input assignments dependent on the con
fi
guration:
Con
fi
guration
1)
Inputs
I01
I02
I03
I04
I05
I06
I07
I08
00:Free
RF*
V1*
V2*
V3*
VZ*
RV1 UP*
RV2
DOWN*
Free*
01:ZA_IO
RF
V1
V2
V3
VZ
RV1 UP
RV2
DOWN
Free*
03:BP_IO
RF
V1
V2
V3
VZ
RV1 UP
RV2
DOWN
Free*
08:KN_IO
RF
V1
V2
V3
VZ
RV1 UP
RV2
DOWN
Free*
11:NL_IO
RF
V1
V2
V3
VZ
RV1 UP
RV2
DOWN
Free*
13:SS_IO
RF
V1
V2
V3
VZ
RV1 UP
RV2
DOWN
V4*
15:ZA_BIN
RF
DIR
BIN0
BIN1
BIN2
Free*
Free*
Free*
16:WL_IO
RF
V1
V2
V3
VZ
RV1 UP
RV2
DOWN
V4*
21:ST_IO
RF
V1
V2
V3
VZ
RV1 UP
RV2
DOWN
Free*
24:CSILVA
RF
BIN0
BIN1
BIN2
Free*
RV2
DOWN
RV1 UP Free*
25:S+S
SBIN2 SBIN1 SBIN0
RV1
UP
RV2
DOWN
Free*
Free*
RF*
27:MAS_BIN
RF
DIR
MBIN0 MBIN1 MBIN2
BR1
BR2
Free*
30:KS_IO
RF
V1
V4
V2
VZ
RV1 UP
RV2
DOWN
V3*
31:KL_IO
V4
V1
V2
V3
VZ
RF+RV1
RF+
RV2
PA-
RA*2
32: S_SMART
RF*
V1*
LZ*
V3*
V5*
RV1 UP*
RV2
DOWN*
Free*
1)
For the description of the con
fi
gurations, see chapter "Parameter List/Control Menu" in the operating instructions - Part 2.
*
The function of the inputs can be changed
Information
To be able to travel, at least the following input signals need to be present:
•
Controller enable
•
Speed
•
Direction default
Original operating instructions
ZAdynpro
–
Part 1
Electrical installation
R-TBA17_01-GB 1837 Index 004
Part.-No. 00163459-GB
21/64
5