9
Enclosure
9.1
Technical data for ZAdynpro
ZAdynpro
011
013
017
023
032
ZAdynpro article number
352250
352251
352252
352253
352254
Electrical data
Mains connection voltage
[V]
3~ 180 ... 440 absolut
Mains frequency
[Hz]
50 / 60 (
±
1,5 Hz)
Typ. motor output (400 V)
[kW]
4.6
5.5
7.5
11
14
Duty cycle at rated current and clock frequency
8 kHz
[%]
40
Nominal current for 40% duty cycle and switch-
ing frequency 8 kHz
fi
xed
[A]
11
13
17
23
32
Nominal current for 40% switch-on duration and
switching frequency 12 kHz
fi
x
1)
[A]
9
11
15
20
27
Nominal current for 40% duty cycle and switch-
ing frequency 16 kHz
fi
x
1)
[A]
8
10
13
17
23
Max. operating current (for max. 10 s)
[A]
20
24
31
42
58
Power loss at nominal current, switching fre-
quency 8 kHz and 40% duty cycle
[W]
137
150
186
230
295
Power loss at nominal current, switching fre-
quency 16 kHz and 40% duty cycle
[W]
221
239
296
350
432
Power losses during standstill
[W]
24
25
26
27
27
Power loss in standby
[W]
≤
3.0 W
≤
6.0 W
Switching frequency
[kHz]
4 ... 16
Motor frequency
[Hz]
max. 200
Max. terminal cross-section line/motor/brake
chopper/brake resistor
[mm
2
]
16
Ambient conditions
The user must ensure that the speci
fi
ed ambient conditions are observed.
Protection rating (as per DIN EN 60529)
IP20
Ambient temperature for operation
[
°
C] 0 ... 55, from 40
°
C power reduction by1.66% per 1 k temperature
increase
Relative humidity
[%]
90 / condensation prohibited
Installation height
[m
ü
ber
NN]
bis 2000, ab 1000 m Leistungsreduzierung um 1% pro 100 m
Storage and shipping temperature
[
°
C]
-20 to +60
Degree of soiling (in acc. with DIN EN 61800-5-
1)
2
Physical data
Weight ZAdynpro
[kg]
4.5
4.5
4.6
6.0
6.1
Dimensions h x w x d
[mm]
290 x 150 x 195
390 x 151 x 195
1)
with a variable switching frequency (
power component/M_PWM=AUTO
menu), there is no reduction in power
Original operating instructions
ZAdynpro
–
Part 1
Enclosure
R-TBA17_01-GB 1837 Index 004
Part.-No. 00163459-GB
48/64