background image

Configuration

36

BitStorm 4800 Express Model 4821-A2 Installation Guide

4821-A2-ZN21-30

Using the CLI 

A command line interface (CLI) can be used to configure and monitor the 
unit. The CLI is available from a PC or terminal connected to the Console 
port, or from a Telnet session with the device.

The following commands are available:   

Descriptions of some essential configuration commands follow.

Table 4: 

CLI Commands

Command

Function

clear

Clear the system log.

configure

Enter Configuration mode.

copy

Copy from one file to another.

date

Set the time zone and date format.

end

If user is in Administrator mode, shifts to User mode; if 

user is in User mode, positions interface at top of menu 

tree.

exit

Terminate current session.

firmware

Download or apply new firmware.

paging

Enable or disable paging (

more

 prompt) for this 

session.

privilege

Enable administrator mode.

restart

Restart a unit.

show

Display configuration, statistics, and status.

technical-support

Display information for contacting technical support.

test

Test the system.

Summary of Contents for 4821-A2

Page 1: ...BitStorm 4800 Express Model 4821 A2 Installation Guide March 2006 Document Part Number 4821 A2 ZN21 30...

Page 2: ...r Zhone Technologies reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Zhone Technologies to notify any person of such re...

Page 3: ...eemed a material breach hereof User may make a reasonable number of copies solely for archival or disaster recovery and subject to the restrictions imposed by copyright law but may not modify or other...

Page 4: ...he receptacle is not properly grounded the installation must not continue until a qualified electrician has corrected the problem If a 3 wire grounding type power source is not available consult a qua...

Page 5: ...ides optical coupling to the telecommunication network Once a Class 1 laser product is installed the equipment is to be considered to be a Class 1 Laser Product Appareil Laser de Classe 1 The customer...

Page 6: ...radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Th...

Page 7: ...number of terminals allowed to be connected to a telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringe...

Page 8: ...8 BitStorm 4800 Express Model 4821 A2 Installation Guide 4821 A2 ZN21 30...

Page 9: ...ing Configurations 17 Mounting Brackets 17 Installing the Brackets for Rack Mounting 17 Installing the BitStorm 4800 Express Into a Rack 19 Installing the BitStorm 4800 Express on a Wall 21 Installing...

Page 10: ...itStorm 4800 Express Startup Procedure 39 Login 39 Management Modes 39 Startup Procedure for Inband Management 40 Startup Procedure for Out of Band Management 40 Using the Web Interface 41 System User...

Page 11: ...800 Express Chapter 3 LEDs Explains the meaning and usage of the front panel LEDs Chapter 4 Configuration Describes the minimal configuration steps required to prepare the BitStorm 4800 Express for re...

Page 12: ...torm 4800 Express Model 4821 A2 SNMP Reference Contains the information necessary to use Simple Network Management Protocol SNMP to configure and monitor the BitStorm 4800 Express BitStorm 6051 POTS S...

Page 13: ...re provided The unit also may be managed using a network manager such as the Paradyne GrandVIEW Element Management System EMS BitStorm 4800 Express IP DSLAM models and features are listed in Table 1 B...

Page 14: ...5 mm ETSI rack ETSI brackets are available from Paradyne See Appendix B Equipment List As many BitStorm 4800 Express units may be mounted in a standard rack as there are 1 75 inch 44 45 mm spaces in t...

Page 15: ...ire Category 5 or better unshielded twisted pair UTP cable The BitStorm 4800 Express to a network Port 1 10 100BaseT 8 position modular plug and 8 wire Category 5 or better unshielded twisted pair UTP...

Page 16: ...Storm 4800 Express is shipped in a cardboard shipping container Carefully remove the unit from its shipping container and check for physical damage If the unit shows signs of shipping damage notify yo...

Page 17: ...marked with Paradyne Part Number 868 6282 0020 are shipped with the unit Two brackets suitable for a 21 inch 535 mm rack marked ETSI are available from Paradyne as a separate feature see Appendix B E...

Page 18: ...nch racks or six machine screws for 23 inch racks provided with the mounting brackets in the hardware kit 4 Attach the brackets appropriate to your rack size Tighten all screws firmly 02 17324 23 inch...

Page 19: ...mounting screws and self retaining nuts for rails with unthreaded screw holes To install the BitStorm 4800 Express into a rack 1 Determine where in the rack you will mount the BitStorm 4800 Express I...

Page 20: ...0BT CONSOLE PORT2 10 100BT PORT3 LINK ACT GigE STATUS ALARM TEST ALARM 1 2 23 DSL PORTS 1 24 1000BT 24 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 POTS 1 24 POTS 1 24 PORT1 10 100BT CONSOLE P...

Page 21: ...mm plywood not drywall To install the BitStorm 4800 Express on a wall 1 Identify the 6 32 x 3 16 inch flat head screws provided in the hardware kit and the brackets suitable for a 23 inch rack Two sc...

Page 22: ...25 mm apart Do not completely tighten the screws Leave them so their heads are about 1 4 inch 6 mm from the wall 7 Hang the unit from the wood screws to verify that the screws are properly placed The...

Page 23: ...lf or desktop as a standalone unit or in a stack 1 Locate the rubber feet in the hardware kit provided with the unit 2 Turn the unit upside down on a work surface Squares stamped into the bottom of th...

Page 24: ...Installation 24 BitStorm 4800 Express Model 4821 A2 Installation Guide 4821 A2 ZN21 30...

Page 25: ...00 Express has a large variety of possible cabling configurations This chapter describes all possible connections not all of which are required z DSL Ports on page 26 z 10 100BaseT Uplink Port 2 on pa...

Page 26: ...1 24 connector 2 If the connector for your cable has a short captive screw attach the cable to the DSL PORTS 1 24 connector and fasten it to the jack screw with its short captive screw 3 If the connec...

Page 27: ...Uplink Port 2 Port 2 is the uplink for the DSLAM A straight through cable can be used regardless of the destination interface since the port automatically distinguishes between an MDI and an MDIX To...

Page 28: ...en an MDI and an MDIX To use Port 1 as the out of band management port 1 Connect an 8 position modular cable to Port 1 2 If the BitStorm 4800 Express is in a rack fasten the cable to a rail with a cab...

Page 29: ...1 Configure the terminal or terminal emulation program to use the following parameters Speed 9600 bps Data bits 8 Parity None Flow Control None Stop bits 1 2 Determine and procure the proper Data Term...

Page 30: ...Connect the DB9 plug connector to the CONSOLE port socket 3 If the modem will be permanently connected fasten the connector to the Management Module with its captive screws If the BitStorm 4800 Expre...

Page 31: ...p a ring terminal onto the stripped end of 14 AWG or heavier copper ground wire 2 Remove the screw marked by the ground symbol at the right side of the front panel 3 Fasten the ring terminal to the fr...

Page 32: ...nect the BitStorm 4800 Express to a power source 1 Insert the supplied power cord into the power socket on the back of the unit 2 If the BitStorm 4800 Express is in a rack dress the power cord to the...

Page 33: ...nk LEDs Activity LEDS DSL Ports LEDs PORT1 10 100BT CONSOLE PORT2 10 100BT STATUS ALARM TEST 25 47 27 29 31 33 35 37 39 41 43 45 26 48 28 30 32 34 36 38 40 42 44 46 1 23 3 5 7 9 11 13 15 17 19 21 2 24...

Page 34: ...Ethernet link present Ethernet Link present Ethernet link is present but port is administratively disabled Activity Green Off On No data is being transferred Data is being transferred STATUS Green Off...

Page 35: ...eed Initial configuration is performed using the Command Line Interface CLI The CLI is available from a terminal or PC connected to the CONSOLE port or through the management port Port 1 Additional co...

Page 36: ...s Command Function clear Clear the system log configure Enter Configuration mode copy Copy from one file to another date Set the time zone and date format end If user is in Administrator mode shifts t...

Page 37: ...y ip_address Minimum Access Level Administrator ip_address Specifies the IP address of the default gateway for the management ports Example PDYN configure management default gateway 137 90 127 1 confi...

Page 38: ...bootp ip_address subnet_mask Minimum Access Level Administrator bootp Specifies that a BOOTP server will determine the management IP address ip_address Specifies the management IP address The default...

Page 39: ...rm 4800 Express 1 Connect a PC or terminal to the CONSOLE port See Console Port in Chapter 2 Cabling 2 At the login prompt type admin and press Enter 3 At the password prompt press Enter The default l...

Page 40: ...on the same subnet Startup Procedure for Out of Band Management In out of band management you manage the unit through Port 1 To start up the BitStorm 4800 Express using out of band management 1 To av...

Page 41: ...Password blank Click on OK The web interface screen appears 4 Click on the menu tab appropriate to what you would like to do Configuration To configure the system and interfaces Status To display stat...

Page 42: ...n Apply Keep a record of the new password Configuration Management SNMP SNMP access to the unit is disabled by default The read only community string is public and the read write string is private Com...

Page 43: ...tors on page 44 z Port 1 and Port 2 10 100BaseT Connectors on page 45 z Console Port Connector on page 46 Figure 2 BitStorm 4800 Express IP Front Panel 04 17535 PORT1 10 100BT CONSOLE PORT2 10 100BT S...

Page 44: ...nnector is CA21A Table 5 lists the pin assignments for these interfaces Note that Pins 25 and 50 are not used Table 5 DSL Connector Pinouts DSL Port Connector Pins Ring Tip 1 or 25 1 26 2 or 26 2 27 3...

Page 45: ...on Guide 45 Port 1 and Port 2 10 100BaseT Connectors Port 1 and Port 2 are 8 pin unkeyed modular jacks for a 10 100BaseT interface Table 6 Port 1 and Port 2 Pinouts Signal Pin Transmitted Data 1 Trans...

Page 46: ...onsole Port Connector The CONSOLE port connector is a DB9 socket connector that supports an EIA 232 E circuit as shown in Table 7 Table 7 Console Port Connector RS 232 Signal Directio n Pin Ground Out...

Page 47: ...ss 24 Port IP DSLAM with North America power cord Includes BitStorm 4800 Express 19 and 23 inch mounting brackets and hardware and Installation Guide 4821 A2 427 BitStorm 4800 Express 48 Port IP DSLAM...

Page 48: ...Equipment List 48 BitStorm 4800 Express Model 4821 A2 Installation Guide 4821 A2 ZN21 30...

Page 49: ...netic Compatibility EMC Meets the following standards z EN 300 386 2 z EN 55024 z EN 55022 Class A z FCC Part 15 Class A z VCCI Class A Interfaces z DSL PORTS 50 pin RJ21X Telco type connector z CONSO...

Page 50: ...ption Model 4821 A2 417 12 Watts Maximum Model 4821 A2 427 26 Watts Maximum Model 4821 A2 447 40 Watts Maximum Weight Model 4821 A2 417 11 2 lbs 5 1 kg Model 4821 A2 427 11 2 lbs 5 1 kg Model 4821 A2...

Page 51: ...mand Line Interface CLI 36 commands 36 community strings 42 configuration 35 CLI commands 37 mounting brackets 17 configuring inband management 40 out of band management 40 SNMP parameters 42 connecto...

Page 52: ...2 self retaining nuts 19 unit into rack 19 unit on wall 21 interfaces 49 J jack screw 26 L LEDs 33 Link LEDs 34 login 39 lug for grounding 31 M management modes 39 Management port cabling 28 connector...

Page 53: ...e 20 procedure 19 related documents 12 Return key 36 RJ21X connectors 44 RJ45 pinouts 46 S shelf installation 23 shipping carton 16 site preparation 14 site requirements 14 49 SNMP configuring paramet...

Page 54: ...54 BitStorm 4800 Express Model 4821 A2 Installation Guide 4821 A2 ZN21 30...

Reviews: