090317-NUT-SPLIT-MULTISPLIT-EN
16/24
EN
•
Display panel (Floor/Ceiling models ACF / ATF / ATR)
This is located at the top centre of the front panel of the indoor unit.
k
= Infrared receiver
l
= “OPERATION“ Operating status indicator
m
= “TIMER” Timer setting indicator
j
= Indicator for warm start-up or defrosting “DEFROST” (heating mode)
n
= Indicator for unit safety mode (see self-diagnosis)
o
= Manual start up button (override)
5- INSTRUCTIONS FOR USE
•
General instructions
To obtain the best performances in terms of comfort and regulation, the following points should be taken into
account:
- Orient the air flows correctly so that they do not blow directly onto people.
- Adjust the set temperature so that it is not too excessive and so that the difference between the inside and the
outside temperature is not too large (it is recommenced that this difference does not exceed 8°C).
- Close all doors and windows in order to maintain energy efficiency and avoid severe condensation (in cooling
(COOL) mode or dehumidify (DRY) mode).
- During the summer months, if possible close shutters on windows to avoid direct sunlight in the room.
- Do not install objects that may obstruct the air inlet or outlets of the indoor and outdoor units, performance could
decrease considerably and the appliance could become a safety hazard.
- Clean the filters periodically otherwise efficiency may be affected.
- Before long periods during which the product will not be in use, operate the product in fan only mode for half a
day to dry the internal parts then disconnect the power supply and remove the batteries from the remote control.
- When re-starting the product after a long interval, re-connect the main power supply and wait for half a day before
operating the product.
For information:
-The compressor will only re-start 3 minutes after a power cut or a regulation stop (anti-short protection cycle).
-Following a power cut, the product will re-start in the operating mode it was set to before the power cut occurred.
-In heating mode, the indoor unit fan will only begin operating when the temperature of the heat exchanger is high
enough to avoid any problems of discomfort.
•
Wall-mounted model
The automatic air outlet vents and sweeping vents must be carefully positioned:
- A mechanical vent enables the airflow to be directed downwards.
This vent is controlled by the remote control (see above).
Note:
-Do not attempt to move the indoor unit mechanical vent manually.
- Do not operate the indoor unit with the mechanical vent in the closed or almost closed position (loss of efficiency
or risk of safety hazard).
-It is not possible to command the mechanical vent when the product is stopped (OFF).
- Manual deflectors enable the airflow to be directed to the left or the right.
- Use the lever to position the manual vents, taking care not to touch the fan blades or the horizontal mechanical
vent, and also not to damage the manual vents.