Installation and operating instructions
53
10.2 AC output data
Type
TLC 10K
TLC 15K
TLC 17K
TLC 20K
Power connection
Three phase
Rated output power
10000 W
15000 W
17000 W
20000 W
Max. output active power
10000 W
15000 W
17000 W
20000 W
Max. output apparent power
10000 VA
15000 VA
17000 VA
20000 VA
Rated grid voltage
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 240/415V
AC voltage range
(1)
160 V to 300 V
Operating range at AC mains
frequency 50 Hz
(2)
45 Hz to 55 Hz
Operating range at AC mains
frequency 60 Hz
(2)
55 Hz to 65 Hz
Rated output current at 220 V
15.1 A
22.7 A
25.7 A
30 A
Rated output current at 230 V
14.5 A
21.7 A
24.6 A
28.9 A
Rated output current at 240 V
13.9A
20.8 A
23.6 A
27.7 A
Max. continuous output current
16A
24 A
25.8 A
30 A
Power
factor
VDE-AR-N 4105
0.85ind - 0.85cap
Other safety
>0.97 at 20% load, >0.99 at 100% load
Inrush current(peak and duration)
143A@89us
143A@89us
143A@89us
143A@89us
Max. output fault current
(peak and duration)
s
s
s
ms
Max. output overcurrent protection
300V,25A,
TYPE C
circuit
breaker
300V, 40A,
TYPE C
circuit
breaker
300V, 40A,
TYPE C
circuit
breaker
300V, 40A,
TYPE C
circuit
breaker
Harmonic distortion (THD) at Pac,r
< 3%
Night-time power loss
< 1 W
Standby power loss
< 12 W