Alternator
Alternator maintenance
When washing and cleaning the tractor protect the alternator from penetration of water or
diesel fuel! During operation the alternator must not be disconnected from the battery! The alternator
must never be put in operation without load, i.e. with the conductor disconnected from the '+B'
terminal and the '+D' terminal connected. Such a condition may induce an extremely high voltage
when the engine speed is increased, which would destroy the semiconductors! Never short-circuit
any alternator terminal during operation! The alternator must not be additionally excited. Such an
intervention would damage the semiconductors. Ensure perfect electric connection of the alternator
terminals and proper grounding of the alternator! Poles of the alternator may not be re-versed even
for a short time!
Electric installation overload
Charging is monitored by the red indicator on the
combined dashboard instrument.
During repairs of the tractor by electric welding
all the conductors must be disconnected from the
alternator. Protect the '+B' conductor from a short-
circuit.
C15N135
Is signalized by the selected display changing to a display
with a symbol of a battery. It is a condition when electric
installation of the tractor has such take-off, that the
alternator performance is not sufficient to accumulator
charging. If this state occurs, turn off a device or increase
engine revolutions, load of electric installation drops and
originally selected display is displayed.
The operation of tractor in the electric
installation overload mode can lead to accumulator
depletion.
C15N144
ELECTRIC INSTALLATION
133
Summary of Contents for CRYSTAL Series
Page 1: ...150 160 Tractor is Zetor Since 1946 OPERATOR S MANUAL CRYSTAL 1 2015...
Page 3: ...2...
Page 11: ...10...
Page 89: ...NOTES 88...
Page 95: ...NOTES 94...
Page 123: ...NOTES 122...
Page 127: ...NOTES 126...
Page 131: ...NOTES 130...
Page 163: ...NOTES 162...
Page 167: ...NOTAS 166...
Page 180: ...NOTES 179...