Fast heating of the cabin area
Fast cooling of the space of the cabin
Operation of heating or air-condition with tractor´s work
Immediately after cooling the cabin
Proceed accordingly:
1 - Turn the heating valve control (A) to the position on the
right (fully opened heating valve).
2 - Set air circulation in cabin control (D) to the position of
inner circulation.
3 - Select applicable gear of the ventilator run (position 1,
2, 3) by ventilator control (B).
4 - Set the expiration under the requested angle to avoid
direct fanning of the people in the cabin.
5 - After heating the space of the cabin, set the air
circulation in the cabin control (D) to the position of
sucking the outer air - see fig. F_02_17b position (a)
F_02_18a
Proceed accordingly:
1 - Switch the heating valve control lever (A) to the
position to the left
2 - Set the air circulation in the cabin lever (D) to the
position of outer air sucking
3 - Select an applicable gear of the ventilator run (position
1, 2, 3) by ventilator control (B)
4 - Switch the air-condition system by a switch (C)
5 - Set expiration under the requested angle so that direct
fanning of people in the cabin does not occur (the
possibility of illness due tointensive cooling of parts of
body).
F_02_18
With engaged inner recirculation of air is the inflow of
fresh air closed and there is foul air in the space of the
cabin by operator. This state can cause the feeling of
fatigue and there can also be penetration of dust to the
cabin because of the loss of surplus pressure.
Note:
Set the control (D) according to individual
requirements on temperature to the position between (a)
and (b) so that the ventilator sucks the air from the outside
of the cabin through filters, when working.
When spraying pesticides and using the
heating filter with active carbon, the recirculation
controller should be in position 'air is drawn into from
the outside' and the fan controller should be in the
position 'fan maximum work' to create overpressure
in the cabin.
F_02_19
Immediately after cooling the cabin and lowering the inner
temperature on the required values, we recommend the
following:
- Switch over the control of air circulation (D) from position
(b - air re-circulation) to position (a - outer air suction)
- Do the continuous regulation of the air temperature with
air condition on by opening the heating valve (A). The air
entering the cabin from expiration is not so intensively
dried with this setting.
- Continuous temperature control with air-condition on can
be also done by lowering the output of ventilator by
switching the control (B) to position 1 or 2.
F_02_20
ACQUAINTANCE WITH THE TRACTOR
38
Summary of Contents for CRYSTAL Series
Page 1: ...150 160 Tractor is Zetor Since 1946 OPERATOR S MANUAL CRYSTAL 1 2015...
Page 3: ...2...
Page 11: ...10...
Page 89: ...NOTES 88...
Page 95: ...NOTES 94...
Page 123: ...NOTES 122...
Page 127: ...NOTES 126...
Page 131: ...NOTES 130...
Page 163: ...NOTES 162...
Page 167: ...NOTAS 166...
Page 180: ...NOTES 179...