135
ELECTRO-HYDRAULIC SYSTEM
F_02_174
DESCRIPTION OF ELECTRO-HYDRAULIC EHR-B LIGHT FAILURE
flashing combination of
diagnostic LED (7)
long
pause
No
o
f
flashing
short
pause
No
o
f
flashing
localization of failure
possible reason of failure
3x
1x right tensiometer pin (A)
failed tensiometer pin
3x
2x left tensiometer pin (A)
failed contact or interrupted wire of tensiometer pin
wire short circuit of tensiometer pin
possible overload of tensiometer pin
failed control potentiometer (3)
3x
4x speed lowering control (3)
failed contact or disconnected wire of control
failed control potentiometer (6)
3x
6x regulation mode control (6)
failed contact or disconnected wire of control
Summary of Contents for 106 41 forterra turbo
Page 1: ......
Page 2: ......
Page 7: ...7 LOCATION OF SERIAL NUMBERS Z 8641 Z 9641 Z 10641 Z 11441 F_02_154...
Page 8: ...8 LOCATION OF SERIAL NUMBERS Z 11741 F_02_187a...
Page 20: ...20 NOTE...
Page 34: ...34 TRACTOR SURVEY B21a...
Page 36: ...36 TRACTOR SURVEY F54b...
Page 47: ...47 TRACTOR SURVAY F_02_150...
Page 50: ...50 NOTE...
Page 62: ...62 NOTE...
Page 83: ...83 NOTE...
Page 84: ...84 NOTE...
Page 90: ...90 NOTE...
Page 99: ...99 NOTE...
Page 100: ...100 NOTE...
Page 106: ...106 NOTE...
Page 117: ...117 NOTE...
Page 118: ...118 NOTE...
Page 124: ...124 NOTE...
Page 136: ...136 NOTE...
Page 145: ...145 NOTE...
Page 146: ...146 NOTE...
Page 153: ...153 NOTE...
Page 154: ...154 NOTE...
Page 161: ...161 NOTE...
Page 162: ...162 NOTE...
Page 185: ...185 NOTE...
Page 186: ...186 NOTE...
Page 197: ...197 NOTE...
Page 198: ...198 NOTE...
Page 209: ...209 NOTE...
Page 210: ...210 NOTE...
Page 217: ...217 SCHEDULED TECHNICAL MAINTENANCE LUBRICATING CHART TRACTORS Z 8641 Z 11741 F_02_155...
Page 226: ...226 NOTE...
Page 257: ......