Function
code
Name
Description
Setting
range
Factory
default
F7.17
T1 run mode selections
0
F7.18
T2 run mode selections
0
F7.19
T3 run mode selections
0
F7.20
T4 run mode selections
0
F7.21
T5 run mode selections
0
F7.22
T6 run mode selections
0
F7.23
T7 run mode selections
0
F7.24
Current running
multi-speed(Reserve)
F7.25
Current running time
(Reserve)
F8.00
PID feedback trait selection
0
:
Positive trait 1
:
Negative trait
0-1
0
F8.01
PID give signal source
0
:
Keyboard number given
1
:
Keyboard Potentiometer given
2
:
AVI
3
:
ACI
0-3
0
F8.02
PID feedback signal source
0
:
AVI 1
:
ACI
0-1
0
F8.03
Keyboard number PID given
The given value when the PID given source is
Keyboard number setting
PID range
lower limit
-
PID range
upper limit
0.5
F8.04
PID instruction acceleration and
deceleration time
0.0-100.0s
0.0
F8.05
PID control deviation limit
0.0-100.0%
0.0
F8.06
PID control deviation limit
keeping time
0.0-6000.0s
0.0
F8.07
PID deviatiom upper limit
0.0-100.0%
100.0
F8.08
PID deviatiom lower limit
0.0-100.0%
0.0
F8.09
Proportion gain
0.00-600.00
25.00
F8.10
Integral time
0
:
No
Integral time
0.0-100.0s
1.0
F8.11
Differential coefficient
0
:
No
Differential
coefficient
0.00-10.00s
0.00
F8.12
PID output upper limit
0.0-100.0%
100.0
F8.13
PID output lower limit
0.0-100.0%
0.0
F8.14
PID output filter time
0.00-10.00
0.00
F8.15
Feedback fault action selection
0
:
Run at the upper limit frequency
1
:
Run at the lower frequency limit
2
:
Run according to the digital set frequency
3
:
Decelerate to stop
4
:
Free stop
0-4
2
F8.16
PID feedback loss detection
value
0.0-100.0%
0.0
F8.17
PID feedback loss detection time
0.0-100.0s
1.0
F8.18
PID feedback over-limit detection
value
0.0-100.0%
100.0
F8.19
PID feedback over-limit detection
time
0.0-100.0s
1.0
F8 group: PID Control, MPPT And PV Pump Parameters
0
:
Forward, Select acceleration time 1
1
:
Forward, Select acceleration time 2
2
:
Reverse, Select acceleration time 1
3
:
Reverse, Select acceleration time 2
0-3
15