PULSAR
®
PLUS III-S, III-S6, and VI-S SUCTION BLAST CABINETS
Page 20
© 2021 CLEMCO INDUSTRIES CORP.
www.clemcoindustries.com
Manual No. 30421
NOTE: The blue insert on the adjustment knob locks and
unlocks the knob, which prevents unintentional
adjusting. While the knob is down, in the lock position,
slide the insert to either side to lock it and back to center
to unlock it, as shown in Figure 21.
Figure 21
5.8.3
As the filter cartridge cakes with dust, differential
pressure increases, and the pulse-pressure setting may
not adequately clean the cartridge (does not reduce
differential pressure below 4" WC, as noted on the
differential-pressure gauge). When differential pressure
reaches 4” WC, increase pulse pressure by increments
of 10 psi, up to the maximum of 100 psi.
5.8.4
When the maximum pulse pressure of 100 psi is
reached and pulsing does not lower differential pressure
below the changeover pressure of 4" WC, decrease
pulse OFF time to 20 seconds, per Section 5.9.2.
5.8.5
When differential pressure stays above 4" WC.
after increasing pulse pressure to 100 psi and
decreasing OFF time to 20 seconds, replace the
cartridge, per Section 7.14.
5.9
Digital Pulse-Control Timer
The pulse timer is attached to the diaphragm pulse valve
located on the dust collector pulse reservoir, as shown in
Figure 20.
5.9.1 Operating principles
NOTE: There is no need to set the timer functions or
subranges.
If the timer function is accidentally changed, refer to
Section 5.9.4 to reset it to Function "A".
If timer subranges are accidentally changed, refer to
Section 5.9.5 to reset them to factory settings.
5.9.1.1
The LED display comes on the green start
pushbutton is pressed and power is supplied to the timer.
TEST
of
f
on
on
TEST
of
f
on
on
FACTORY SETTINGS
Figure 22
5.9.1.2
The timer is factory set at 40 seconds OFF and
150 milliseconds (0.15 second) ON, as shown in Figure 22.
Every 40 seconds, the cartridge is pulsed for 0.15 second.
5.9.2
Resetting pulse OFF time (time between each
pulse) ‒ Figure 23
NOTE: The numbers shown in Figure 23 signify the
following step numbers:
1. Make sure the OFF subrange is set to seconds. The
sec (seconds) indicator light should be lit, as shown in
Figure 23. If the subrange is other than seconds,
reset it as noted in Section 5.9.5.1.
2. Press the left "off" (arrow down) button until "OF"
appears briefly on the LED display.
3. To decrease OFF time (for example, to change pulse
OFF time from 40 seconds to 20 seconds), press the
left "off" (arrow down) button until 20 seconds shows
on the display.
4. To increase OFF time (lengthen time between pulses
from 20 seconds to 40 seconds), press the right
"on/arrow up" until 40 seconds shows on the display.
When the new OFF time appears on the display do not
press anything; after a few seconds, the display starts
flashing, indicating the new time is being saved. Once
UNLOCKED
LOCKED
Push insert to center
to unlock.
Push insert to either
side to lock.
15
The min (minute) and sec
(seconds) indicator lights
are both lit (indicating the
subrange is set for
milliseconds) 10 times
the value shown on the
display, or 0.15 seconds
(150 milliseconds).
ON TIME
40
OFF TIME
The sec (seconds)
indicator light is lit
(indicating the
subrange is set for
seconds) and time is
set for 40 seconds.