Section 5.9.2. Switch the power toggle switch to ON to
start the exhauster and pulse cycle.
7.16
Clean Dust-Collector’s Inline Filter – Figure 52
7.16.1
To avoid cartridge pulsing during cleaning, make
sure power is OFF (red pushbutton is pressed). Refer to
the matching step numbers in Figure 52 and clean the
filter as follows:
1. Remove the filter and tubing from the lower snubber
by pushing in on the snubber’s retaining collar and
pulling the tubing from the snubber, per instructions in
Section 7.9.
2. Push the locking tab UP to release it from the small
projection on the bottom cap.
3. Rotate the bottom cap to the left to release it and
pull the cap down to remove it from the filter body.
Note:
The filter element is loose at this point and may fall
off the bottom cap.
4. Remove the filter from the bottom cap and remove
accumulated dust from the filter and filter body. Replace the
filter if the element or body is damaged or otherwise faulty.
5. Place the filter onto the bottom cap and insert the
bottom cap into the filter body. Rotate the bottom cap
while gently pushing it upward until it moves into place.
Push the bottom cap against the bottom of the filter body
and turn it to the right until the projection is below the
locking tab.
6. Pull the locking tab down, over the projection to lock
the cap to the body.
7. Replace the tubing into the snubber, per Section 7.9.
7.17
Clean Dust-Collector’s Snubber Fittings
Figure 52
7.17.1
Continually high differential pressure can be
caused by the tiny orifice on the back side or the
snubber being plugged with caked dust.
7.17.2
Remove the tubing from the snubber, as
instructed in Section 7.9.
7.17.3
Remove the lower snubber from the bushing in
the dust-collector port. Clean dust from the orifice at the
backside of the fitting and reinstall the fitting. Replace
the fitting if it is damaged or otherwise faulty.
7.17.4
Replace the tubing into the snubber fitting.
7.17.5
Repeat the process on the upper snubber.
Figure 52
3
Projection
Upper Snubber
Lower Snubber
Inline Filter
Dust Collector
2
4
6
5
Directional arrow
must point UP.
White Tubing
Green Tubing
1, 7