HOME AUTOMATION

PG13

ZCOM230 |CONTROL PANEL | COMANDO 230V

ZCOMV2 |CONTROL PANEL | COMMANDO 24V

Discovering the origin of the problem

1.  Open  control  board  and 

check if   it   has   230V   power   

supply

2. Check input fuses

3. Disconnect the motor from 

control  board  and  test  them 

by  connecting  directly  to 

power supply in order to find 

out if they have problems.

4. If the motor works, the pro

-

blem is on the control board. 

Pull it out and send it to our 

ZERO technical services for 

diagnosis.

5. If the motor doesn’t work, 

remove them from installation 

site and send to our ZERO te-

chnical services for diagnosis.

Check all motion axis and associated motion systems related with the motor and the gate to find out what is the problem.

1.  Check  capacitors,  testing 

operator  with new capacitors;

2. If capacitors are not the 

problem,  disconnect  motors 

from control  board  and  test  

them by connecting directly to 

power supply in order to find 

out if they have problems. 

3. If the motors work, the pro

-

blem  is  from  control  board. 

Pull it out and send it to our 

ZERO technical services for 

diagnosis;

4. If the motors doesn’t work, 

remove them from installation 

site and send to our ZERO te-

chnical services for diagnosis

All ZERO   control  boards have LEDs that easily allow to conclude which devices are with anomalies. All safety devices LEDs 

(DS) in normal situations remain On. All “START” circuits LEDs in normal situations remain Off.

If LEDs devices are not all On, there is some security systems malfunction   (photocells, safety edges), etc.

1 • Close with a shunt all safety systems on the control board (check manual of the control board in question). If the automa

-

ted system starts working normally check for  the problematic device. 

2 • Remove one shunt at a time until you find the malfunction device  .

3 • Replace it for a functional device and check if the motor works correctly with all the other devices. If you find another one 

defective, follow the same steps until you find all the problems.

If  “START” circuits LEDs are turn On, there is a control device sending permanent signal.

1 • Disconnect all wires from START terminal input (terminal 3).

2 • If the LED turned Off, try reconnecting one device at  a time until you find the defective device.

In case described procedures fell, remove control board and sendto our technical services for diagnosis.

Check all motion axis and associated motion systems related with the motor and the gate to find out what is the problem.

1.  Check  capacitors,  testing 

with new  capacitors;

2. If capacitors are not the 

problem,  disconnect  motor 

from  control  board  and  test 

it  by  connecting  directly  to 

power supply in order to find 

out if it is broken;                                       

3. If the motor doesn’t work, 

remove  it  from  installation 

site and send to our ZERO te-

chnical services for diagnosis.

4.  If  motor  work  well  and 

move gate at full force during 

the    entire  course,  the  pro

-

blem  is  from  controller.  Set 

force using trimmer on the 

board.  Make  a  new    working  

time  programming,  giving 

suffient time for opening and 

closing with appropriate force.

5. If this doesn’t work, remo

-

ve control unit and send it to 

ZERO technical services servi-

ces.

NOTE: Setting force of the controller  should  be  sufficient to make the gate open and close without stopping, but should stop 

and invert with a little effort from a person. In case of safety systems failure, the gate shall never cause physical damaged to 

obstacles (vehicles, people, etc.).

Summary of Contents for COMANDO 230V

Page 1: ...G1 ZCOM230 CONTROL PANEL COMANDO 230V zero HOME AUTOMATION USER MANUAL AND CONFIGURATION ZCOM230 VER1 0 01052018_REV1 IT EN FR zero HOME AUTOMATION COMANDO CONTROL UNIT SLIDING GATES 230V made in ital...

Page 2: ...zero HOME AUTOMATION PG2 ZCOM230 CONTROL PANEL COMANDO 230V zero HOME AUTOMATION...

Page 3: ...nd provide this manual to user Keep remote controls away from children to prevent the au tomated system from being activated involuntarily The customer shall not under any circumstances attempt to rep...

Page 4: ...ly supports 40W If the consumption is higher intersperse a power relay Capacitator 13 and 15 You should connect the capacitator between the outputs 13 and 15 3 DIP SWITCH FUNCTION DIP 1 ON The SOFT ST...

Page 5: ...rns off NOTE If you select a button other than the n 2 for pedestrian opening the control board will recognize it as complete opening button which means it will override the first pressed button If th...

Page 6: ...REGULATION ANTI CRUSHING The control board has 2 trimmers rotary knobs RV1 Allows the engine sensitivity regulation increases sensiti vity by rotating it in the clockwise direction RV2 Allows the eng...

Page 7: ...G LIMIT SWITCH of motor is reached L03 RED Comes on when the START command is activated and goes off when released L04 RED Always on Goes off when the photocell is intercepted interrupting the PHOTO b...

Page 8: ...other configuration see the DIP SWICH paragraph OFF DIP 5 ON OFF DIP 6 ON OPENING LIMIT SWITCH READING DISABLED OFF OPENING LIMIT SWITCH READING ENABLED DIP 7 ON CLOSING LIMIT SWITCH READING DISABLED...

Page 9: ...zero HOME AUTOMATION PG9 ZCOM230 CONTROL PANEL COMANDO 230V FLASHING LIGHT COURTESY LIGHT CONNECTIONS PHOTOCELLS CONNECTION...

Page 10: ...rol unit is equipped with a CN2 connector to accommodate a magnetic limit switch module directly welded on control panel on demand and just for Z01 model will be also provided two magnetic stoppers fo...

Page 11: ...zero HOME AUTOMATION PG11 ZCOM230 CONTROL PANEL COMANDO 230V zero HOME AUTOMATION...

Page 12: ...se Unlock motor and move the gate by hand to closed posi tion Lock motor again and turn off power supply for 5 seconds Reconnect it and send start si gnal using transmitter Gate opened but didn t clos...

Page 13: ...control board in question If the automa ted system starts working normally check for the problematic device 2 Remove one shunt at a time until you find the malfunction device 3 Replace it for a funct...

Page 14: ...elow have been applied 2014 35 UE Low voltage Directive 2014 30 UE Electromagnetic compatibility Directive 2014 53 EU RED radio equipment directive EN 301 489 3 V2 1 1 EN 300 220 2 V3 1 1 according to...

Page 15: ...zero HOME AUTOMATION PG15 ZCOM230 CONTROL PANEL COMANDO 230V zero HOME AUTOMATION...

Page 16: ...zero HOME AUTOMATION PG16 ZCOM230 CONTROL PANEL COMANDO 230V zero HOME AUTOMATION ZERO SRLS Via Olona 110 Gallarate VA ITALIA info miozero it www miozero it...

Reviews: