PROGRAMMING THE WORKING TIME AND ENGINE’S PAUSE

STEP 1

With the gate closed, place the DIP 9 to “ON”, press transmit-

ter (already programmed) / START and the gate will start to 

open.

STEP 2

When the gate stops at the open position (opening limit-swi

-

tch is enabled), wait for the desired pause time (*) and give 

a new START to close. This waited time represents the time 

that the engine will PAUSE between the end of the opening 

maneuver and the  automatic closure’s start. This automatic 

closure will only happen if the DIP 4 and 5 are in the selected 

positions to activate it. If during the working time setting you 

would like to activate the automatic closing after photocells  

interruption (3 seconds) just interrupt the photocells signal 

during pause counting time. 

STEP 3

When the gate reaches the closed position, change the DIP 9 

to OFF to finish programming and CODE LED will blink and go 

off. If the DIP SWITCH is leaved ON, the programming won’t 

be finalized.

PROGRAMMING THE PEDESTRIAN WORK TIME

STEP1

With the gate in closed mode put the DIP 9 to ON.

STEP2

Press the button nº2 to start opening the gate. Upon reaching 

the desired position press again the button to stop the engi

-

ne. Wait the desired pause time and give a new START to clo

-

se. This waited time represents the time that the engine will 

wait between the end of the pedestrian’s opening maneuver 

and the automatic closure’s start. Nearing the limit-switch’s 

end, the engine will stop.

STEP 3

The setting is completed, place the DIP 9 to OFF to finalize and 

close the pedestrian programming.

FORCE AND SENSITIVITY REGULATION (ANTI-CRUSHING)

The control board has 2 trimmers (rotary knobs):

RV1 - Allows the engine sensitivity regulation (increases sensiti

-

vity by rotating it in the clockwise direction);

RV2 - Allows the engine power regulation (increases the force 

by rotating in the clockwise direction );

Warning: To use anti-crush function (recommended for small 

gates), it is necessary to regulate first the engine’s power with 

the  trimmer  RV2  and  right  after  the  sensitivity  with  trimmer 

RV1. If you change the engine’s power after performing a Wor

-

king Time and Engine Pause programming , a new one is going 

to be needed.

ILUMINATED LIGHTBULB IN PAUSE TIME 

(10 AND 11 TERMINALS)

01 • If you wish to activate this function, when programming 

work time and engine’s pause at the point 2, do the following 

operation from (*):

•Press the pedestrian transmitter button while the gate is pau

-

sed, between the opening and closing.

NOTE: In case of using the 11 and 12 terminals for the lightbulb, 

the DIP3 must be OFF and the Lightbulb must have a circuit bo

-

ard to make the lamp to blink.

PROGRAMMING SAFETY EDGS FUNCTION (terminal 6)

The control panel could accept wire safety edges and 8.2 Ohm 

resistive edges.

During programming working time the panel recognize by itself 

the type of safety edge installed.

Factory set on wire edge, whit shunt placed on terminal 6 and 

terminal 7.

if you have to change to 8.2 KOhm firstly make the transmitter 

programming and then remove the shunt and place the edge’s 

connection.

NOTE: if LED CODE signal flashing once you powered the control 

panel it means that the safety edge is wrongly configured. 

RESET TO FACTORY DEFAULTS

If the control board blocks and a RESET is needed, follow these 

steps:

- Put DIP 9 to ON position

- Power off the control unit by removing the M1 connectors 

  plug, affter few secons power on.

- Put DIP 9 to OFF position.

Summary of Contents for COMANDO 230V

Page 1: ...G1 ZCOM230 CONTROL PANEL COMANDO 230V zero HOME AUTOMATION USER MANUAL AND CONFIGURATION ZCOM230 VER1 0 01052018_REV1 IT EN FR zero HOME AUTOMATION COMANDO CONTROL UNIT SLIDING GATES 230V made in ital...

Page 2: ...zero HOME AUTOMATION PG2 ZCOM230 CONTROL PANEL COMANDO 230V zero HOME AUTOMATION...

Page 3: ...nd provide this manual to user Keep remote controls away from children to prevent the au tomated system from being activated involuntarily The customer shall not under any circumstances attempt to rep...

Page 4: ...ly supports 40W If the consumption is higher intersperse a power relay Capacitator 13 and 15 You should connect the capacitator between the outputs 13 and 15 3 DIP SWITCH FUNCTION DIP 1 ON The SOFT ST...

Page 5: ...rns off NOTE If you select a button other than the n 2 for pedestrian opening the control board will recognize it as complete opening button which means it will override the first pressed button If th...

Page 6: ...REGULATION ANTI CRUSHING The control board has 2 trimmers rotary knobs RV1 Allows the engine sensitivity regulation increases sensiti vity by rotating it in the clockwise direction RV2 Allows the eng...

Page 7: ...G LIMIT SWITCH of motor is reached L03 RED Comes on when the START command is activated and goes off when released L04 RED Always on Goes off when the photocell is intercepted interrupting the PHOTO b...

Page 8: ...other configuration see the DIP SWICH paragraph OFF DIP 5 ON OFF DIP 6 ON OPENING LIMIT SWITCH READING DISABLED OFF OPENING LIMIT SWITCH READING ENABLED DIP 7 ON CLOSING LIMIT SWITCH READING DISABLED...

Page 9: ...zero HOME AUTOMATION PG9 ZCOM230 CONTROL PANEL COMANDO 230V FLASHING LIGHT COURTESY LIGHT CONNECTIONS PHOTOCELLS CONNECTION...

Page 10: ...rol unit is equipped with a CN2 connector to accommodate a magnetic limit switch module directly welded on control panel on demand and just for Z01 model will be also provided two magnetic stoppers fo...

Page 11: ...zero HOME AUTOMATION PG11 ZCOM230 CONTROL PANEL COMANDO 230V zero HOME AUTOMATION...

Page 12: ...se Unlock motor and move the gate by hand to closed posi tion Lock motor again and turn off power supply for 5 seconds Reconnect it and send start si gnal using transmitter Gate opened but didn t clos...

Page 13: ...control board in question If the automa ted system starts working normally check for the problematic device 2 Remove one shunt at a time until you find the malfunction device 3 Replace it for a funct...

Page 14: ...elow have been applied 2014 35 UE Low voltage Directive 2014 30 UE Electromagnetic compatibility Directive 2014 53 EU RED radio equipment directive EN 301 489 3 V2 1 1 EN 300 220 2 V3 1 1 according to...

Page 15: ...zero HOME AUTOMATION PG15 ZCOM230 CONTROL PANEL COMANDO 230V zero HOME AUTOMATION...

Page 16: ...zero HOME AUTOMATION PG16 ZCOM230 CONTROL PANEL COMANDO 230V zero HOME AUTOMATION ZERO SRLS Via Olona 110 Gallarate VA ITALIA info miozero it www miozero it...

Reviews: