Problem
Procedure
Behavior
Procedure II
Door doesn’t work
Make sure you have 230V
power supply connected to
control board and if it is wor
-
king properly.
Still not working.
Consult a qualified ZERO tech
-
nician.
Motor doesn’t move but
makes noise
Unlock motor and move the
gate by hand to check for
mechani cal problems on the
movement
Encountered problems?
Consult an experienced gate
expert.
The gate moves easily?
Consult a qualified ZERO
technician.
Motor opens but doesn’t
close
Unlock motor and move the
gate by hand to closed posi
-
tion.
Lock motor again and turn off
power supply for 5 seconds.
Reconnect it and send start si-
gnal using transmitter.
Gate opened but didn’t close
again.
Check if there is any obstacle
in front of the photocells;
Check if any of the control
-
devices (key selector, push
button, video intercom, etc.)
of the gate are jammed and
sending permanent signal to
control unit;
Consult a qualified ZERO tech
-
nician.
Gate doesn’t make complete
route
Unlock motor and move ate
by hand to check for mecha
-
nical problems on the gate
Encountered problems?
Consult an experienced gate
expert.
The gate moves easily?
Consult a qualified ZERO tech
-
nician.
LED CODE Blinking
Check the safety devices connections and DIP 8 position.
TROUBLESHOOTING