CONTENTS

 1. 

SAFETY INSTRUCTIONS

 

STANDARDS TO FOLLOW 

2. 

THE CONTROL BOARD

 

TECHNICAL SPECIFICATIONS

 

PROGRAMMING PRE-RECOMENDATIONS

3. 

DIP SWITCHES

 

DIPPERS FUNCTION’S BOARD

4. CONFIGURATION

 

INSTALATION PROCESS

5. TROUBLESHOOTING

 

FINAL CONSUMERS INSTRUCTIONS

 

INSTRUCTIONS FOR SPECIALIZED INSTALLERS

7. 

WIRING DIAGRAM

 

CONTROL BOARD COMPONENT CONNECTION

1. SAFETY INSTRUCTIONS

STANDARDS TO FOLLOW 

ATTENTION:

• To ensure the safety of people, it is important that you read all 

the following instructions. Incorrect installation or incorrect use 

of the product can cause physical injury and material damage.

• Keep these instructions in a safe place for future reference.

• This product was designed and produced strictly for the use 

indicated in this manual. Any other use, not expressly indicated 

here, could compromise the good condition/operation of the 

product and/or be a source of danger.

• ZERO SRL is not responsible for the improper use of the pro

-

duct, or other use than that for which it was designed.

• ZERO SRL is not responsible if safety standards were not taken 

into account when installing the equipment, or for any defor-

mation that may occur to it.

• ZERO SRL is not responsible for the safety and proper opera

-

tion when using components not sold by them.

• Do not make any modifications to the operator components 

and / or their  accessories.

• Before installation unplug the automatism from the source 

of power.

• The installer must inform the client how to handle the pro-

duct in case of emergency and provide this manual to user.

• Keep remote controls away from children, to prevent the au-

tomated system from being activated involuntarily.

• The customer shall not, under any circumstances, attempt to 

repair or tune the automatism. Must call qualified technician 

only.

• Connect the automatism to a 230V plug with ground wire.

• Control board for indoor use.

 

2. 

THE CONTROL BOARD

TECHNICAL SPECIFICATIONS

          

Power supply:

230V 50/60Hz

Lightbulb’s output:

AC230V 40W max

Motor’s output:

AC230V 750W max

Aux. accessories output: 

AC24V 8W máx

Working temperature:

-20°C a +50°C

Radio Receptor:

Incorporated 433,92 Mhz

OP Transmitters:

12 bits ou Rolling Code

Max. memory capacity: 

200 codes max

CONNECTOR’S DESCRIPTION

M2 Connector

01 • Closing limit-switch input signal (NC)

02 • Opening limit-switch input signal (NC)

03 • Open/close transmitter button’s input (NA)

04 • Safety device input - complete direction inversion (NC)

05 • Pedestrian transmitter button’s input (NC)

06 • Safety device input - 2 seconds inversion (NC)

07 • Safety device input common / STARTs

08 • Power supply output for accessories 0V

09 • Power supply output for accessories 24V AC - 8W máx.

M1 Connector

10 • Light bulb connection’s output (230Vac)

11 • Light bulb connection’s output - common

12 • Light bulb connection’s output or courtesy light 

13 • Motor’s output - Opening

14 • Motor’s output - Common

15 • Motor’s output - Closing

16 • 230V line input (neutral)

17 • Not used

18 • 230V line input (phase)

M3 Connector

19 • Antenna 

20 • Antenna cable screen

M4 Connector

21 • Place Shunt for motors up to 500kg (included)

22 • Remove Shunt for motors up to 500kg

PROGRAMMING PRE-RECOMENDATIONS

Before proceeding to the control board configuration, note the 

following points listed in the table below in order to better un

-

derstand the control board function:

Summary of Contents for COMANDO 230V

Page 1: ...G1 ZCOM230 CONTROL PANEL COMANDO 230V zero HOME AUTOMATION USER MANUAL AND CONFIGURATION ZCOM230 VER1 0 01052018_REV1 IT EN FR zero HOME AUTOMATION COMANDO CONTROL UNIT SLIDING GATES 230V made in ital...

Page 2: ...zero HOME AUTOMATION PG2 ZCOM230 CONTROL PANEL COMANDO 230V zero HOME AUTOMATION...

Page 3: ...nd provide this manual to user Keep remote controls away from children to prevent the au tomated system from being activated involuntarily The customer shall not under any circumstances attempt to rep...

Page 4: ...ly supports 40W If the consumption is higher intersperse a power relay Capacitator 13 and 15 You should connect the capacitator between the outputs 13 and 15 3 DIP SWITCH FUNCTION DIP 1 ON The SOFT ST...

Page 5: ...rns off NOTE If you select a button other than the n 2 for pedestrian opening the control board will recognize it as complete opening button which means it will override the first pressed button If th...

Page 6: ...REGULATION ANTI CRUSHING The control board has 2 trimmers rotary knobs RV1 Allows the engine sensitivity regulation increases sensiti vity by rotating it in the clockwise direction RV2 Allows the eng...

Page 7: ...G LIMIT SWITCH of motor is reached L03 RED Comes on when the START command is activated and goes off when released L04 RED Always on Goes off when the photocell is intercepted interrupting the PHOTO b...

Page 8: ...other configuration see the DIP SWICH paragraph OFF DIP 5 ON OFF DIP 6 ON OPENING LIMIT SWITCH READING DISABLED OFF OPENING LIMIT SWITCH READING ENABLED DIP 7 ON CLOSING LIMIT SWITCH READING DISABLED...

Page 9: ...zero HOME AUTOMATION PG9 ZCOM230 CONTROL PANEL COMANDO 230V FLASHING LIGHT COURTESY LIGHT CONNECTIONS PHOTOCELLS CONNECTION...

Page 10: ...rol unit is equipped with a CN2 connector to accommodate a magnetic limit switch module directly welded on control panel on demand and just for Z01 model will be also provided two magnetic stoppers fo...

Page 11: ...zero HOME AUTOMATION PG11 ZCOM230 CONTROL PANEL COMANDO 230V zero HOME AUTOMATION...

Page 12: ...se Unlock motor and move the gate by hand to closed posi tion Lock motor again and turn off power supply for 5 seconds Reconnect it and send start si gnal using transmitter Gate opened but didn t clos...

Page 13: ...control board in question If the automa ted system starts working normally check for the problematic device 2 Remove one shunt at a time until you find the malfunction device 3 Replace it for a funct...

Page 14: ...elow have been applied 2014 35 UE Low voltage Directive 2014 30 UE Electromagnetic compatibility Directive 2014 53 EU RED radio equipment directive EN 301 489 3 V2 1 1 EN 300 220 2 V3 1 1 according to...

Page 15: ...zero HOME AUTOMATION PG15 ZCOM230 CONTROL PANEL COMANDO 230V zero HOME AUTOMATION...

Page 16: ...zero HOME AUTOMATION PG16 ZCOM230 CONTROL PANEL COMANDO 230V zero HOME AUTOMATION ZERO SRLS Via Olona 110 Gallarate VA ITALIA info miozero it www miozero it...

Reviews: