4-12
!
!
A
B
C
D
E
Charger LED Indicators
A. Ammeter
The Ammeter LED is
an amber indicator
that indicates the
amount of current
output, and should
gradually ramp down
from “IIIIII” to “I”.
B. 80% Charge
The 80% Charge
LED is an amber
indicator. If it is on
solid, the bulk
charge phase is complete, 80% charged. Charger is
now in absorption phase. If the indicator is flashing,
there are two issues that can cause this:
•
The charger and BMS are balancing
•
The BMS is stopping the charge because one or
more cells have reached maximum voltage.
C. 100% Charge
The 100% Charge LED is a green indicator. If it is on
solid, the charging is complete and the charger will
enter maintenance mode. If it is flashing, the
absorption phase is complete and the charger is in
finish phase.
D. AC ON
The AC ON LED is an amber indicator. If it is on
solid, the AC power is good. If it is flashing, the AC
voltage is low. Check for proper voltage, and if an
extension cord is being used, verify that it is of the
correct length. Maximum length is 7.6 m (25 ft.)
12-AWG.
E. Fault
The Fault LED is a red indicator indicating a charger
error. If it is flashing, reset the charger and see
section 6, Troubleshooting.
Summary of Contents for XU 2012
Page 1: ...ZERO X ZERO MX ZERO XU 2012 Owner s Manual ...
Page 5: ...TOC 4 NOTES ...
Page 27: ...2 6 NOTES ...
Page 49: ...3 22 NOTES ...
Page 78: ...5 3 ZERO A C D E F B See Bolt Torque Table on page 5 2 ...
Page 79: ...5 4 G H J I K See Bolt Torque Table on page 5 2 ...
Page 109: ...5 34 NOTES ...
Page 127: ...6 18 NOTES ...
Page 135: ...7 8 NOTES ...