Summary of Contents for Chilli Master

Page 1: ...CHILLI MASTER CONTROLLER OPERATING MANUAL...

Page 2: ......

Page 3: ...when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual...

Page 4: ...er Control 3 2 Manual Control 3 2 Preheat 3 4 Dimmer Laws 3 5 Topset 3 6 Reset 3 7 DMX Controls 3 7 Chilli Net 3 10 Supply Status 3 12 Output Calibration 3 12 Diagnostics 3 12 Area Control 3 13 Timed...

Page 5: ...master controller which can be set up and operated via the front panel controls The manual concludes with a chapter on the Technical Specification of the Master Controller Conventions Throughout this...

Page 6: ...setted if required to limit its maximum output level The network can be programmed with up to 12 memories per area Each networked dimmer grabs its own outputs and stores them internally when instructe...

Page 7: ...ovided Poke the Chilli network cable through the hole in the wallplate see Figure 2 3 Hook the rear of the case over the hook in the wallplate and refix the case to the wallplate with the screws remov...

Page 8: ...2 2 Chilli Master Controller 73 861 00 Issue 3 Installation Figure 2 4 Figure 2 5 Figure 2 6...

Page 9: ...ed dimmers is not responding Further details of the above faults can be obtained via the Diagnostics menu Menu Structure If the Master Controller is in the alarm state all menu access will be disabled...

Page 10: ...loption from the menu Set Chan Level Press the ENT key The LCD shows A01 Channel xx Level xxx A cursor is shown in the Channel field The channel number defaults to 1 When the cursor is displayed in th...

Page 11: ...oves to the Level field When the cursor is displayed in the Level field Keypad Enter the required channel level 0 100 using the numeric keys then press the ENT key Cursor Keys Use the cursor keys to a...

Page 12: ...meric keys 0 9 then press the ENT key The cursor returns to the Channelfield Cursor Keys When the cursor is in the Channel field pressing the A key increments the channel number pressing the B key dec...

Page 13: ...the Law field and the cursor moves to the Law field Cursor Keys Press the A key to increase the channel number by 1 press the B key to decrease the channel number by 1 As the channel number changes t...

Page 14: ...pset level for the selected channel is shown in the Levelfield and the cursor moves to the Level field When the cursor is in the Levelfield enter the required level using the numeric keys 0 9 then pre...

Page 15: ...results in a different DMX patch to resetting each of the individual dimmers DMX Controls This option allows the user to set the DMX start address for the entire network patch individual or blocks of...

Page 16: ...ddress then press the ENT key to patch the channel and return the cursor to the Channelfield Pushing the ESC key at any point on this screen will return the LCD to the Set DMX Patch screen Block Patch...

Page 17: ...to select the Fade to Black option Press the ENT key The LCD returns to the DMX Input screen Fade to Memory use the cursor keys to select the Fade to Memory option The LCD shows DMX Fail Mode Fade to...

Page 18: ...the Chilli Net screen Auto Assign Complete AddDimmer The Add Dimmer function is used when a new dimmer is added into an existing Chilli network After validation the master controller will add the dim...

Page 19: ...This option provides the user with various information on the dimmers connected to the Chilli network Select the Network Info option from the Chilli Net menu Network Info Press the ENT key The LCD sho...

Page 20: ...ey The LCD shows the following screen Dimmer Number XX Use the numeric keys or cursor keys to select the required dimmer number then press the ENT key If the selected dimmer is a Spice dimmer the LCD...

Page 21: ...pad Enter the required area number 1 10 using the numeric keys then press the ENT key Cursor Keys Use the cursor keys to select the area number then press the ENT key The area is assigned to the maste...

Page 22: ...Press the ENT key to enter the Timed Event sub menu The following menu options are available Display Date and Time Set Time Set Date Event Use the cursor keys to select the required menu option Press...

Page 23: ...ber Press the ENT key to save the data and return to the Event Area screen Pressing the ESC key will quit the operation and return to the Event Area screen Event Time This option allows the user to se...

Page 24: ...elected event Select the Action Memory option Action Memory Press the ENT key The LCD shows Area xx Ev xx Memory xx The top line of the LCD displays the area number and event number for information on...

Page 25: ...onfirm the memory selection The LCD shows Area xx Mem xx Fade Time xx The Area and Mem fields on the top line are for information only The cursor is displayed in the Fade Time field Use the numeric or...

Page 26: ...ies are indicated by a next to the memory number and cannot be edited Press the ENT key to confirm the memory selection Assuming the selected memory is programmed the networked dimmers output the sele...

Page 27: ...to select the first step in the sequence then press the ENT key The cursor moves to the Memory field Use the numeric or cursor keys to select a memory number Press the ENT key to assign the memory to...

Page 28: ...quence 1 Use the numeric or cursor keys to select the required sequence 1 3 then press the ENT key The LCD shows the following Push ENT key to clear sequence Press the ENT key The sequence is cleared...

Page 29: ...level is displayed Use the numeric or cursor keys to set the required lock level 0 4 Press the ENT key The LCD returns to the Security screen Security Code This option allows the user to change the lo...

Page 30: ...rs the Alarm State All menu access via the control panel is disabled The main screen on the LCD shows the following message PANEL LOCKED ALARM ACTIVE Alarm Off Message When the Master Controller recei...

Page 31: ...ions 5 way 2 part rising clamp screw terminal connector with the following pin configuration Pin 1 12V Orange pair Pin 2 CAN H Blue White Pin 3 CAN L Blue Pin 4 0V Green pair Pin 5 Shield Brown pair M...

Page 32: ...4 2 Chilli Master Controller 73 861 00 Issue 3 Technical Specification...

Page 33: ......

Page 34: ...Zero 88 Lighting Ltd Usk House Llantarnam Park Cwmbran Gwent NP44 3HD United Kingdom Tel 44 0 1633 838088 Fax 44 0 1633 867880 e mail sales zero88 com Web www zero88 com 24 hour answerphone...