7.0 > Maintenance and Troubleshooting
7.1 > Module Removal Procedure
WARNING:
DO NOT disconnect Module wires while system is in operation. Follow Module
manufacture instructions for disconnecting Module wiring.
In order to remove a Module from the array, start at the top of the column where the Module is
located and remove each Module, moving down the column, until you have removed the desired
Module. Starting at the top, remove the two Interlocks connected to the top Module at the top edge
(Figure 7.1A). Also remove any Leveling Feet connected to that Module. (Figure 7.1A) Then, making
sure you have disconnected the wiring according to the Module manufacturer’s instructions, remove
the Module by pivoting it up and out, or reverse drop-in procedure (Figure 7.1B). Then, using the Flat
Tool, rotate both Interlock Zeps from each of the Interlocks connected to the top edge of the second
Module (going down the column) to positions #1 (Figure 7.1C). Once the Interlock Zeps have been
rotated, place the Flat Tool in the gap between the two Modules, attach it between the Interlock lug
and the flange (Figure 7.1D), and disengage the Interlock lugs from the Module groove by prying down
on the Flat tool (Figure 7.1D). Next, slide the Interlocks to either side until the Interlock is no longer
connected to two adjacent Modules (Figure 7.1E). It may be necessary to lightly tap the Interlock to
cause it to slide. After removing any Leveling Feet connected to the next Module, and disconnecting
Module wires, remove the next Module by pivoting up and out. Repeat this procedure going down the
row until the desired Module is removed.